Supplied By www.heating spares.co Tel. 0161 620 6677
15
Part No. 5000893
Commissioning
Fig. 20
Note:
Check the gas rate check, the gas
consumption after 3 minutes running should
be approximately 2.91 m
3
/hr (102.8 ft
3
/hr).
9. Turn the temperature selector spindle (if
fitted) from right to left , there will be a
noticeable change in the outlet
temperature. Turn the rod back to the
right (maximum).
10. Turn OFF the hot water outlet and press
the OFF button on the appliance.
Remove the pressure gauge and replace
the screw and sealing ring.
11. Relight the pilot. Turn ON a hot water
outlet and check for gas soundness at
the pressure test point.
12. Turn OFF the hot water outlet. Slide the
bottom cover onto the appliance. Ensure
that the temperature selector spindle is
aligned with the selector knob, push the
bottom cover and with slight adjustment
the selector will positively locate on the
spindle.
•
Explain to the user how to operate the
appliance.
•
Show the user the position of the
Identification Badge.
•
Advise the User that to ensure long life
and safe, trouble free operation, the
appliance must be inspected and
serviced at regular intervals by a
competent person.
•
Leave these Instructions with the User
future use.
Fig. 19