20 Wiring diagrams
25
Switching on
The unit starts up approx. 50 seconds after
switching on with switch S1 (room lighting) and
switch S2.
Switching off, scenario 1
The unit has an overrun time of approximately 6
minutes after switching off with switch S1 (room
lighting) and then switches off.
Switching off, scenario 2
The unit is switched off directly with switch S2, i.e.
regardless of the room lighting.
ER-AP 60 F, ER-APB 60 F
ER-AP 100 F, ER-APB 100 F
F standard switching:
The F fan is designed for installation in window-
less, dark rooms. The unit is switched on wire-
lessly through the brightness of the room lighting
by a light control unit. The unit starts up after ap-
proximately 50 seconds.
The minimum switch-on brightness is 30 lx on the
front of the cover.
Switching on
The unit starts up approx. 50 seconds after
switching on the room lighting with switch S1.
Switching off
The unit has an overrun time of approximately 6
minutes after switching off the room lighting with
switch S1 and then switches off. For the unit to
switch off, the room must be dark (max. lighting
strength at the front of the cover is 0.3 lx).
F switching variant