Mahr 106 ES Operating Instructions Manual Download Page 1

1

Digitaler Winkelmesser

Digital Protractor

Mesureur d’angles digital

106 ES

Bedienungsanleitung

Operating Instructions

Instructions de Service

3755670

0218

Mahr GmbH

Standort Esslingen

Reutlinger Str. 48, 73728 Esslingen  

Tel. +49 711 9312-600, Fax +49 711 9312-756

[email protected], www.mahr.de

Summary of Contents for 106 ES

Page 1: ...Mesureur d angles digital 106 ES Bedienungsanleitung Operating Instructions Instructions de Service 3755670 0218 Mahr GmbH Standort Esslingen Reutlinger Str 48 73728 Esslingen Tel 49 711 9312 600 Fax...

Page 2: ...ten m ssen Verschmutzungen nach Be endigung des Einsatzes mit einem trockenen Tuch entfernt werden Anschlie end die metallischen Teile mit l konservieren Ein verschmutztes Geh use sollte nach dem Eins...

Page 3: ...ttons simultaneously until the display goes blank 5 sec Change of Battery Changement de pile 60 C 10 C 40 C 10 C MODE ON OFF SET 106 ES BAT SET 0 01 Lithium 3V Typ CR2032 Batterie einlegen Insert batt...

Page 4: ...pour changement de batterie 10 Bouton MODE 11 Bouton SET ON OFF Mehrfunktionsanzeige 1 Anzeige Messbereich 2 Messwert 3 Anzeige Batterieende 4 Masseinheit 5 Anzeige Funktionssperre der Taste MODE 6 M...

Page 5: ...mode Mode de param trage Bet tigungsdauer Time of activation Dur e d operation Gew hlter Modus Selected mode Mode select 1 s 1 s OFF SET HOLD OFF Data Messmodus Meas mode Mode mesure Einstellmodus Set...

Page 6: ...se of this equipment in an environmentally friendly way in accordance with the applicable EU Directives WEEE Waste Electrical and Electronic Equipment and the German National Electrical and Electronic...

Page 7: ...n the instrument The display shows the last mode setting and reading Setup mode This is the active mode after a battery change or a reset of the unit 0 01 Ref 0 00 Unit selection A short push on the M...

Page 8: ...vates clears the HOLD function Comments Each time the Hold function is set the data is transmitted to the OPTO RS interface If the request light of the OPTO RS plug is active the Hold function is clea...

Page 9: ...ument Cette fonction permet de retrouver la configuration initiale de l instrument Activer MODE et SET simultan ment jusqu l extinction de l affichage Ce dernier affiche RESET un court instant d s qu...

Page 10: ...SET puis effectuer une courte pression sur SET et MODE simultan ment jusqu l affichagede MOdE 0 verrouill ou MOdE1 actif Contr ler ensuite l chelle de mesure active L indicateur C devient actif pour c...

Page 11: ...ode einschieben Verkehrtes Einf hren f hrt nicht zur Besch digung des Steckers oder Messger tes Introducing OPTO RS plug Plug in the connector with opto electronic component windows facing the user Th...

Page 12: ...einer Fehlmessung zeigt das Messger t die Meldung Err0 an und bertr gt gleichzeitig die Meldung ERR an den OPTO RS Ausgang Fehlermeldung l schen Taste SET kurz dr cken um die Messung neu zu starten o...

Reviews: