5.3 electrical installation 

Protect your device with separate pre-fuse (not 
included  in  the  scope  of  delivery)  according  to 
the  information  provided  under  point  2  „Tech-
nical Data“.

make sure that the pre-fuse is not overloaded by 
other devices (e.g. fan heaters, deep freezers).

Check  whether  the  main  voltage  and  frequen-
cy correspond to the information on the rating 
plate.

Insert the plug into the corresponding grounded outlet.

5.4 adjustment of the portafilter rest

The grinder is designed so that most off different portafilter from 
various espresso machines fit into the rest, item 12, for hands-
free grinding operation. 

Proceed as follows for the adjusting the portafilter rest, item12:

•  Keep the grinder switched off. 

Slightly loosen the screws, item 13, with a allen wrench 3mm, in 
case  of  100-120v-model  with  a  screwdriver  and  pull  down  the 

portafilter rest, item 12.

In  case  the  portafilter  rest  does  not  fit  to  your  espresso  ma-
chine´s portafilter, please contact your local dealer. he will ar-
range a different portafilter rest.

Push  the  portafilter  of  your  espresso  machine  onto  the  start  / 
stop switch between the portafilter mounting and the portafilter 
rest. 

Now push up the portafilter rest until the portafilter holds on its 
own. Refasten the screws, item 13.

6. Operation

Only  use  the  PEAK  espresso  grinder  for  whole  roasted  coffee 
beans. See chapter 1.3.

Observe the safety instructions under 1.2!

The max. permissible operating cycle is 5sec ON and 10sec OFF,
i.e. four double shots per minute - if you operate with fans (switch
position II, item 17, according to the information under point 2
„Technical Data“. Do not exceed the maximum allowable contin-
uous grinding time of 20 minutes. Afterwards, allow the grinder
to cool down before next operation.

Summary of Contents for PEAK

Page 1: ...h O R e C a G a ST R O G R I n D e R 1 Operating Instructions PEAK Single Espresso Grinder...

Page 2: ...assuring you of high quali ty grinding of espresso an other types of coffee beans Read through an observe the operating instructions so you and your customers will thoroughly enjoy the PEAK Please sto...

Page 3: ...ions 17 Table of Contents 1 Safety 4 1 1 Symbols 4 1 2 Safety instructions 4 1 3 Usage purpose 5 1 4 User requirements 5 2 Technical Data 5 3 Description 6 4 Safety Devices of the Grinder 7 5 Set Up a...

Page 4: ...or lack of experi ence and or for lack of knowledge unless they are supervised by an appointed person for their safety or got instructions by that person how the ma chine is to be used Never submerge...

Page 5: ...n with fans Please request technical data for other voltages and frequencies from the manufacturer or dealer Do not exceed the maximums allowable contin uous grinding time of 20 min Afterwards allow t...

Page 6: ...rew for grinding adjustment lid 5 Grind adjustment lid 6 Grinding fineness scale 7 Display 8 Single Shot pre selection button 9 Double Shot pre selection button 10 Spout adjustable 11 Portafilter moun...

Page 7: ...until it clicks in Secure the hopper with the lock screw item 2 by using a allen wrench 2mm or in case of 100 120V model use a screwdriver Open the hopper slider item 16 in the adapter 4 Safety Device...

Page 8: ...with a allen wrench 3mm in case of 100 120v model with a screwdriver and pull down the portafilter rest item 12 In case the portafilter rest does not fit to your espresso ma chine s portafilter please...

Page 9: ...ter of your espresso machine into the portafilter rest Grinding starts and ends automatically 6 1 6 Break function If you pull out the portafilter while grinding the process will be interrupted The LE...

Page 10: ...e shot time Press and hold pre selec tion button double shot item 9 for 3 seconds Adjust the time by short pressing the pre selection button single shot item 8 to reduce the time or pre selection butt...

Page 11: ...g discs Current temperature inside the grinder Grinding time Single shot mode on Example view Default settings Counter Light ON Temperature OFF Alarm MAIN MENU Light off Color change mode ON 0 0 0 0 1...

Page 12: ...of all barista shots can be reset Reset the counter Press and hold for 3 sec Single shot counter shows the total number of all single shots can be reset Total shot counter hows the total number of all...

Page 13: ...s the display will show the warning message to clean the grinder The limit for the next cleaning can be ad justed The limit for the next grinding discs replacement can be adjusted After grinding a def...

Page 14: ...esired grinding fineness Clean the grinding mecha nism as described and re move the foreign object Observe the safety instruc tions Reset the grinding time Defect The grinder does not start the dis pl...

Page 15: ...t the grinder and grind through all GRINDZ into your port a filter or a separate bin several shots needed Open the hopper slider and grind appr 2 3 double shots of coffee in order to purge the residue...

Page 16: ...y foreign objects fall into the grind ing mechanism Inspect the grinder regularly for damage par ticularly to the electrical cable plug etc Any required repairs may only be conducted by authorized spe...

Page 17: ...non authorized personnel MAHLK NIG GmbH Co KG Destrict court Hamburg HR A 5 074 The personally liable shareholder associated company MAHLK NIG mbH Registered at country court Hamburg HR B 45 324 Manag...

Page 18: ...H O R E C A G A ST R O G R I N D E R 18 Notes...

Page 19: ...H O R E C A G A ST R O G R I N D E R 19 Notes...

Page 20: ...H O R E C A G A ST R O G R I N D E R 20 Notes...

Page 21: ...R O G R I N D E R 21 MAHLK NIG GmbH Co KG Tilsiter Stra e 142 22047 Hamburg Germany Phone 49 40 69 69 40 0 Fax 49 40 69 39 721 office mahlkoenig de www mahlkoenig de December 2015 Subject to change wi...

Reviews: