Fault
Cause
Remedy
• Motor blocked
• Foreign objects/
beans jammed in
the grinder mech-
anism
• Outlet is clogged
• Measurement
coil on the power
supply is faulty
Press the Prog bu on. An-
other grinder may con nue
to be used
Set the grinding degree of
the aff ected
grinder to coarse. Switch
the grinder off and on again,
start grinding, the grinder
will grind itself clear. Re-
set the grinding degree to
espresso
Contact your supplier using
the address indicated in the
chapter
“
Service
”
.
“TRIAC GRINDER
X
WITHOUT FUNC-
TION” appears on
the display
• Triac is not
switched through
(optocoupler is
faulty)
• Grinder plug is not
plugged in
• Fuse is faulty
• Triac is faulty
• Condenser is
faulty
• Thermal cut-out
in motor is faulty
(0A)
• Circuit board fault
Press the Prog bu on. Anoth-
er grinder may con nue to be
used
Contact your supplier using
the address indicated in the
chapter
“
Service
”
.