L A D E N M Ü H L E N | S H O P G R I N D E R
5. Setting-up and Basic Adjustment
A grinding test run is carried out on each grinder in the manufac-
turer‘s factory. This is why you may fi nd ground material residue
in the grinding mechanism!
5.1 Setting-up Area
Place the grinder on a level surface free from vibration.
Never operate the grinder in moist, or even
worse, in wet surroundings.
5.2 Installation
You have received your grinder in operating condition. Now you
only need to connect it to a power supply system. Proceed as fol-
lows:
Protect your device with a separate pre-fuse
(not included in the scope of supplies) according
to the information provided in „Technical data“
under 2.
Make sure that the pre-fuse is not overloaded
by other consuming devices (e.g. fan-forced
heaters, deep freezers).
4. Safety Devices
Thermal overload circuit breaker
The motor of the grinder is protected by an overload circuit
breaker, which interrupts the electric circuit of the motor when
the device is subjected to electric overloading. To be able to re-
start the grinder, the reset button on the side of the casing must
be pressed.
The user has no infl uence whatsoever on this
operation. In case of repeated tripping of the cir-
cuit breaker, an expert must be consulted since
this could cause damage to the motor winding.
Motor protector (winding shield)
The grinder is protected against thermal overloading by a motor
protector (thermostat, inserted in the winding). Whenever the
winding of the motor heats up to an impermissible level, the mo-
tor protector interrupts the electric circuit of the motor.
Following a cool-off phase (approx. 1 hr.), the motor protector is
switched on again automatically and the grinder can be re-start-
ed.
7