25
BA060801-en
The following variables can be set:
Variable Designation
Description
Default
Unit
1
Single step RPM
Increment of the RPM
1
(1...2000)
min
-1
2
Single step Trq
Increment of the power take-off torque
1
(1...9999)
Nm
3
Warm-up
performance
Warm-up performance standard value
20
(1...9999)
kW
4
Vehicle data entry Activation or deactivation of the vehicle
data entry and the print out
1 = Make
2 = Model
4 = Operating hours
8 = Customer name
The setting is generated by adding up
the desired digits.
e.g.: Print model and customer name:
Variable value is 10 = 2 + 8
15
(0…15)
5
Autom. printout
0 = No print out is done during the
measurement. The print out is created
using the print out menu <F2> .
1 = A print out is created during the
measurement. A copy can be created in
the print out menu <F2>
1
(0...1)
6
Switchover PS/kW Switchover via software by pressing
<P> key in the measurement menu.
0
(0...1)
10
Pulses per litre
Resolution of the consumption meter.
The number of pulses per litre of the
consumption meter are given.
2000
(1...9999)
pulses/l
11
Consumption
measurement time
Measurement interval of the
consumption measurement with
constant RPM or constant torque.
5,00
(0,01...
99.99)
s
12
Consumption
measurement
delay
Time delay until the consumption
values are recorded. Is added to
holding time with discrete
measurement.
0,00
(0…99.99)
s
13
Stamp size
Number of empty lines at the end of a
print out to use a stamp
5
(0…99)
Lines
14
Switch-off time
Time after which the hand terminal
switches off automatically. The switch-
off time is reset if any key is pressed or
an RPM is recognized.
20
(0…999)
Minutes
15
Radio channel
Radio channel of the radio transmission
module
0 = Data transmission per cable
1-3= Radio transmission
2
(0…3)
Channel
no.