4.4.2
Constant Torque
Pos : 68 /T echnisc he Dokumentation/ Leis tung/F unktion/ Abg as/ 06 LPS Tr akt or/ 0801 LPS Z W-500/BA/I nhalt : 0608 Konst antes Drehmoment @ 18\ mod_1254734840399_75. doc x @ 456907 @ @ 1
1 Select suitable transmission/RPM range of the power take-off shaft, switch on shaft.
2 Select measurement method and confirm with <ENTER>.
Measurement with
constant Md <*>
→
3 Enter value for target torque using digit keys.
4 Use <ENTER>-key for confirmation.
Target torque
0.0 Nm
5 Press the accelerator. Target torque is regulated over the
entire RPM range.
Regulate power and engine torque using the accelerator.
6 Display of the target values:
Use the arrow keys to switch between the displays:
0.0 Nm
→
0.0 kW
0 U/m
•
P.t.o. shaft performance
•
P.t.o. shaft torque
P
0.0 kW
Md 0.0 Nm
•
P.t.o. shaft performance
•
P.t.o. shaft RPM
P
0.0 kW
n
0.0
min
-1
•
P.t.o. shaft torque
•
P.t.o. shaft RPM
Md 0.0 Nm
n
0
min
-1
•
P.t.o. shaft consumption
•
P.t.o. shaft RPM
Consumpt. -,- l/h
n
-- min
-1
Reducing the target value by 1 min
-1
(basic setting)
<F5>
Increasing the target value by 1 min
-1
(basic setting)
<F6>
Setting the increment in Variable 2: see "Operation / Setting Menu <F1> / Program Variables".
7 Printing of the current measurement data using the print
menu.
<F2>
and
<ENTER>
8 Enter vehicle data.
9 Printing the current measurement values.
<ENTER>
10 Cancel printout. Signature and stamp are printed.
<ESC>
After measurement, continue driving the p.t.o. shaft without load to cool down the brake.
Pos : 69 /-----Format-----/MANUELLER UMBRUCH Seit enumbr uc h @ 0\ mod_1134403577687_0. doc x @ 1277 @ @ 1