122
BA053101-en
Pos: 424 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1/S/ Überschr ift 1.1: Smart Line Mod ule 16k W und 36kW @ 22\mod_ 1295519277556_ 75.docx @ 963714 @ 2 @ 1
16.2
Smart Line Module 16kW and 36kW
Pos: 425 /Technis che Dok umentation/ Leis tungsmesstechnik/POWE RDYNO/053101 M SR/ BA/Inhalt: 0531 SINAMICS Smart Line Module 16 k W und 36 k W / S ingle M otor Mod ule @ 17\mod_ 1253259413890_75.d ocx @ 444591 @ @ 1
Status
Description, Cause
Remedy
Ready
(H200)
DC link (H201)
Off
Off
Electronics power supply is missing or outside per-
missible tolerance range.
-
Green
Off
The component is ready for operation and cyclic
DRIVE-CLliQ communication is taking place.
-
Orange
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is present.
-
Red
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is too high.
Check supply voltage
Orange
Orange
DRIVE-CLiQ communication is being established.
-
Red
-
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding mes-
sages being reconfigured.
Remedy and
acknowledge fault
Green / Red
-
Firmware is being downloaded.
-
Green /
Orange
or
Red / Orange
-
Component recognition via LED is activated
(Ip0124).
Note:
Both options depend on the LED status when com-
ponent recognition is activated via p0124 = 1.
-
Hazard DC link voltages may be present at any time regardless of the status of the "DC link" LED.
The warning information on the components must be carefully observed!
Pos: 426 /-----Format- ----/MANUE LLE R UMBRUCH Seitenumbruch @ 0\mod_ 1134403577687_0.docx @ 1277 @ @ 1