12
BA022901-en
2.12.2
Cable Remote Control
<EMERGENCY OFF> mushroom button (red)
The emergency off switch is used to quickly switch off the entire control if a
hazard occurs. Once this button has been pressed, the <FAULT> indicator
light lights up. The system’s ready for operation state is restored by turning
the mushroom button to the right.
<MAINS ON> indicator light (white)
Lights up as soon as the power supply was switched on and the PLC is ready
for operation.
<FAULT> indicator light (red)
Lights up when a fault is present:
Oil shortage in the hydraulic unit (continuous light)
Fuse failure in the control cabinet (continuous light)
Approval not given for support feet or ramps (flashing light)
<RESET> pushbutton (blue)
Used to acknowledge emergency off.
<RETRACT SUPPORT FOOT 1 – 4> pushbutton (green)
Used to jointly retract support feet 1 – 4.
<EXTEND SUPPORT FOOT 1 – 4> pushbutton (green)
Used to jointly extend support feet 1 – 4.
[Not assigned]
<LEFT / RIGHT RAMPS> ROTARY SWITCH (black)
Left ramps (entrance) active
Position 0
Right ramps (exit) active
<RETRACT RAMPS> pushbutton (green)
Used to retract (lift) the lamps.
<EXTEND RAMPS> pushbutton (green)
Used to extend (lower) the ramps.
<RAISE LIFTING ROOF> pushbutton (green)
Used to lift the lifting roof.
<LOWER LIFTING ROOF> pushbutton (green)
Used to lower the lifting roof.