Evaluation / Data Logging
1 Use the button <F8 EVALUATION>.
→
The following screen appears:
2 Use the drop-down menus on the right-hand side to select and save up to six test values per
diagram. The number of diagrams which can be saved is not limited.
3 Exit the measurement screen with <ESC>.
Scaling the Power and Load Simulation Graphs
The Power and Load Simulation graphs can be manually scaled as follows:
1 Double-click the upper left- or right-hand
corner of the diagram.
→
An entry field opens.
2 Enter the desired scaling value.
3 Confirm with RETURN or ENTER.
The Power values [kW] are scaled
using the left-hand x-axis, the
additional test values using the
right-hand x-axis.