Progressive Metering –
Progressive Metering allows for more accurate dispenses of selected
components. However, cycle time will be extended by a few additional seconds.
In normal operation blenders target a dispense of the full requested amount in one try. This
almost always works, and generally will fall within acceptable upper and lower error limits. Making
the dispense in one try allows for high throughput rates while still achieving a level of accuracy
acceptable for most processors. When the accuracy of one particular component is critical, or the
process depends on maintaining a tighter tolerance of this component, customers may lengthen
the blend cycle time slightly to achieve this higher level of accuracy.
The Progressive Metering function is used to turn on this function for a selected component. This
sets parameters which will cause the dispense to occur in several progressively smaller
dispenses. This results in a more accurate dispense.
The first dispense targets only 85 percent (the default percentage) of the full required amount.
After careful weighing, each successive dispense targets 50 percent of the remaining shortage.
This continues until the amount reaches, or is within 1 percent of, the target. In this manner the
software "sneaks up" on the target, providing the maximum achievable accuracy possible.
When Progressive Metering is Enabled, then a component is selected and Enabled, the
corresponding PT and RP parameters are set to PT 00085 and RP 00001.
How to use Progressive Metering:
Press
Display will prompt for a password.
(default: 22222)
Then press:
Press
Blender Configuration
Display will show the Blender Configuration categories.
Press
Operating Options
Display will show the Operating Options categories
Press
Progressive Metering
Display will show the Progressive Metering screen with 12
components labeled 1 – 12. Display will also show an Enabled and
Disabled checkbox per component to enable) or disable
Progressive Metering.
Press
To select the component that you want to enable Progressive
metering.
Press
Enabled
To enable Progressive Metering on the selected component.
The Display change to the PT parameter for that component
showing the percentage of the first try % adjustable with the
arrow buttons.
Press
To adjust the first Try percentage. You may change the 85 by
entering a different number using the arrow keys. Too low a
setting will just add time. Too high will cause occasional
overshooting.
Press
To Save and exit or press the red X to cancel
and exit.
End Empty or Full -
END the Cycle with: BIN EMPTY (standard), or BIN FULL
This flag for SPECIAL APPLICATIONS ONLY. Select Standard: end with bin empty or select
Summary of Contents for Weigh Scale Blender 4088 TSC
Page 6: ...6...
Page 10: ...10 Blender Parts Key...
Page 13: ...13...
Page 100: ...100 Technical Drawings...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112 FCA INSTALLATIONDIAGRAM...
Page 113: ...113 WSB 4088 IO wiring diagram 120V...
Page 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Page 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Page 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Page 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Page 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Page 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Page 120: ...120...
Page 138: ...138 Flexbus Lite Wiring Diagrams...
Page 139: ...139...
Page 140: ...140 Flexbus Lite Component Map...