flashes (LOADER 1) or (LOADER 2), depending on which one has the problem. The LT1
and LT2 parameters specify this delay time before alarm.
All circuit boards have provision for connecting level sensor inputs for 2 loaders. When this
loader option is being used, uncovering level sensor 1 will cause pin G (7) of the eight pin
Amphenol plug to be energized. This can be used, through a relay, to drive a loader.
MDI
MLAN Delay Interval (milliseconds) (4088 Standard only)
This parameter controls the delay between when an MLAN TCP/IP packet is
received and the time the MLAN TCP/IP response packet is sent. This parameter
is displayed and stored in milliseconds. Defaults to 0.
COMPONENT PARAMETERS (12 Groups of 15 parameters each)
_TY
Designates material type for this component
_TY is the number that designates if this Component is used and what material TYPE
it is. Material TYPES are REGRIND, NATURAL, ADDITIVE, or NOT USED. This
parameter is stored as a 5 digit number but displayed as a three letter word:
OFF
= Component NOT USED,
REG
= REGRIND,
NAT
= NATURAL,
ADD
= ADDITIVE.
Use the
key to toggle through these four selections.
(All other parameters require input of a 5 digit number.)
The WEIGH SCALE BLENDER handles each DIFFERENTLY in the MATH routines.
REGRIND (PERCENT OF MIX)
Those components that you designate REGRIND will be added as a PERCENT of the
ENTIRE MIX of material.
NATURAL (RATIO TO EACH OTHER)
Those components that you designate NATURAL will be added in the proportion that you
specify them to each other. Their actual percentage of the mix will depend on how much
Regrind is specified and how much Additive is specified.
ADDITIVE (PERCENT OF ALL NATURALS)
Each component designated ADDITIVE will be added as a percentage of all the NATURALS
added together.
If you think of your mix as a RATIO OF WEIGHTS, for example, components 1, 2, 3, 4, and 5
are to be mixed at 100, 50, 5, 20 and 7 pounds respectively, then you may wish to specify
ALL components as NATURALS. In this way weights may be entered just as listed. They
need not add up to any particular number. Components will be dispensed to maintain the
proper specified RATIO to each other component.
If you wish to think of ALL components as PERCENTAGES of THE MIX, percents that
always add up to 100, then you can specify ALL components as REGRIND and enter the
exact percent for each. If ALL components are specified as REGRIND, then all settings must
add up to 100. If the total exceeds 100, an error message will appear.
Summary of Contents for WEIGH SCALE BLENDER WSB-100 Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...