M A G U I R E P R O D U C T S , I N C .
101
W E I G H S C A L E B L E N D E R
Special Tests - Printout Verification
Using the *54 flag the following tests can be made:
If you are running these special tests in the MANUAL or PROGRAM mode, a printout will automatically occur after each test
provided the PRINT flag (*54) is turned on.
Special tests that produce printouts are TIME or CALIBRATE.
TIME
(See KEYPAD, TIME; and PARAMETERS, _LA, for more information)
The TIME function is to determine lag times of different metering devices. It also allows testing of device repeatability. The single
line printout looks like this:
TIME
COMP
1
123
2749
key:
component number
dispense time (in interrupts; 244 = 1 sec.)
weight dispensed
CALIBRATE
(See KEYPAD, CALIBRATE for more information)
The CALIBRATE function allows the controller to rapidly learn the flow rate of the device. It automatically sets the WEIGHT and
TIME parameters that determine metering rate, and the MINIMUM RATE parameter. For more information see PARAMETERS,
_RA, _TI, and _MI. The single line printout looks like this:
CALIBRATE COMP
1
732
8795
15
3465
key:
component number
dispense time
weight dispensed
lag time used
min rate
Material Usage Printout
Pressing the VIEW key followed by the * key will cause all material usage totals to be printed. The (*54) flag need not
be on. These totals are since the last time printed, and since the last time cleared.
Setting the PRT parameter to a time interval number may periodically, and automatically, print this same information.
(See PARAMETER, PRT)
The printout looks like this:
DATE
TIME
CURRENT
11/10/01 16:20:23
LAST
PRINTED
11/10/01 16:10:23
LAST
CLEARED
09/10/01 09:00:04
TOTALS:
GRAND
PCT
CURRENT
PCT
CYCLES
11
7
COMP 1
R 05.0
2.4
4.8
1.5
5.0
COMP 2
N 100
47.4
100.0
28.6
100.0
COMP 5
N 00.5
.4
.99
.2
.99
COMP 6
N 00.5
.4
.94
.2
.91
TOTAL
50.8
30.7
WEIGH SCALE ID# 120
TOTALS ARE IN POUNDS
POUNDS PER HOUR 365.3
The Totals may be in POUNDS or KILOS depending on your selection of weight unit. See: PROGRAM mode, (*89).
Summary of Contents for WEIGH SCALE BLENDER WSB-100 Series
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 128: ...M A G U I R E P R O D U C T S I N C 128 W E I G H S C A L E B L E N D E R...
Page 129: ...M A G U I R E P R O D U C T S I N C 129 W E I G H S C A L E B L E N D E R...
Page 130: ...M A G U I R E P R O D U C T S I N C 130 W E I G H S C A L E B L E N D E R...
Page 131: ...M A G U I R E P R O D U C T S I N C 131 W E I G H S C A L E B L E N D E R...
Page 132: ...M A G U I R E P R O D U C T S I N C 132 W E I G H S C A L E B L E N D E R...
Page 133: ...M A G U I R E P R O D U C T S I N C 133 W E I G H S C A L E B L E N D E R...
Page 134: ...M A G U I R E P R O D U C T S I N C 134 W E I G H S C A L E B L E N D E R...
Page 143: ...M A G U I R E P R O D U C T S I N C 143 W E I G H S C A L E B L E N D E R...