77
Magtrol Model DSP7000 Dynamometer Controller
Chapter 7 – Computer Controlled Operation
OPERA
TION
7.4.3
r
aMp
C
oMManDS
Command
Code
Channel 1
Command
Code
Channel 2
function
explanation
DIL1,xx.xx
DIL2,xx.xx
Sets dynamic scale coefficient. When using dynamic scaling,
XX.XX is multiplied by the I
term to give the end I value.
DPL1,xx.xx
DPL2,xx.xx
Sets dynamic scale coefficient. When using dynamic scaling,
XX.XX is multiplied by the P
term to give the end P value.
DS1,#
DS2,#
Enable or disables dynamic
scaling.
Values for # are:
0 = disable
1 = enable
PD1,#,xx.xx
PD2,#,xx.xx
Program Down (Linear or
Cosin)
Values for # are:
0 = linear
xx.xx = rpm/sec
1 = cosin
xx.xx = length of test in
seconds
PDU1,#,xx.xx PDU2,#,xx.xx Program Down Up (Linear or
Cosin)
Values for # are:
0 = linear
xx.xx = rpm/sec
1 = cosin
xx.xx = length of test in
seconds
PR1
PR2
• Resets ramp up or down.
• Sets speed to maximum
speed.
• Turns brake off.
This command resets the ramp
function, halting the ramp’s
progress, and returns the
motor to free run.
PU1,#,xx.xx
PU2,#,xx.xx
Program Up (Linear or Cosin) Values for # are:
0 = linear
xx.xx = rpm/sec
1 = cosin
xx.xx = length of test in
seconds
S1,xx.xx
S2,xx.xx
Sets start or stop speed for
ramp to #RPM.
When this command is used
with the PD (Program Down)
command, the Controller will
ramp down to this speed and
halt. When this command is
used with the PU (Program Up)
command, the Controller will
load immediately to this speed
and ramp up to free-run.