25
Magtrol Model DSP7000 Dynamometer Controller
Chapter 3 – Installation/Configuration
SETUP
5.b. If using a Powder brake Dynamometer, press ShIFT. The display should appear as follows:
POWER
BRAKE STATUS
SET POINT
SET POINT
P
I
D
TORQUE
SPEED
USER DISPLAY
TSC2
MAX TORQUE
X.XXX
Figure 3–14 TSC2 Powder Brake Setup Menu
Press the ToRqUE UNITS button and use
and
buttons and Decrease/Increase dial to
set desired max torque. Press ShIFT 3 times to complete the initial setup and return to the
main menu.
3.2.5
e
DDy
-C
urrenT
or
p
owDer
B
rake
D
ynaMoMeTer
S
eTup
3.2.5.1
Hardware Connection
USB
PC
M-TEST
Excitation
Torque
TSC 401
Torque-Speed
Conditioner
DES Power Supply
Speed
Eddy-Current (WB)
OR Powder Brake (PB)
Dynamometer
DSP
7001
Dynamometer Controller
Figure 3–15 Eddy-Current or Powder Brake Dynamometer Setup
3.2.5.2
Software Configuration
1. Turn on the DSP7000 and proceed to the dynamometer configuration menu.
See Section
3.2.1 – Dynamometer Configuration Menu
.
2. Press PoWER UNITS until Wb or Pb is reached.
3. Press the MAx SPEED button and use
and
buttons and Decrease/Increase dial to set
desired scale factor. Press SCALE I to add a filter if desired.