57
Magtrol Model DSP7000 Dynamometer Controller
Chapter 5 – Alarm System
SETUP • OPERA
TION
POWER
BRAKE STATUS
SET POINT
SET POINT
P
I
D
TORQUE
SPEED
USER DISPLAY
**** ELECTRICAL ALARM TSCX ****
TORQUE=XXX.XX XX
RPM=X XXXX
Figure 5–24 Electrical Alarm Message Display
5.11.3
T
o
r
eSeT
e
leCTriCal
a
larM
Press any front panel button other than ShIFT. The alarm condition must be cleared before the unit
will return to normal operation.
5.12
ClutCh alarm (wb/pb only)
In tandem setup, the clutch close signal will be sent. After 0.5 seconds, check the clutch closed
signal. If the clutch is open try resending the clutch close signal two more times. If the clutch is
still open go to the alarm.
5.12.1
C
luTCH
a
larM
a
CTion
When there is a clutch failure, the display will flash “CLUTCh FAILURE” (as indicated in
Figure
5–25
).
POWER
BRAKE STATUS
SET POINT
SET POINT
P
I
D
TORQUE
SPEED
USER DISPLAY
**** CLUTCH FAILURE ****
TORQUE=XXX.XX XX
RPM=X XXXX
Figure 5–25 Clutch Alarm Message Display
5.12.2
T
o
r
eSeT
C
luTCH
alarM
Press any front panel button other than ShIFT. The alarm condition must be cleared before the unit
will return to normal operation.