4.4  Operation

Tension is adjusted using the external 10 kohm tension pot.

Rewind taper can be adjusted using the

FULL

 pot.  Counter Clockwise rotation of the

FULL

 pot will

decrease the tension at full roll, thereby increasing the amount of taper.

If the stop multiplier function is used, Clockwise rotation of the

STOP MULT

 pot will increase the

stopping torque.  Clockwise rotation of the

STOP TIME

 pot will increase the time that the stopping torque

is applied.  The

STOP TIME

 may be adjusted from 0.2 to 60 seconds.

5.0   Dancer Applications

5.1   Electrical Connections

Figure 5 shows the connections that are required for the basic dancer system.  They are:

24 vdc power
Current-To-Pressure Transducer
DFP or DFP-2 dancer position sensor
Jumper between terminal 12 & 13

All inputs and outputs have the negative lead referenced to ground.

Figure 5

Dancer Electrical Connections

5.2   Sensor Setup

The DFP or DFP-2 position sensor should be at the center of rotation when the dancer is halfway
through its travel.  This is an approximate adjustment and is intended to center the sensor position to
allow maximum rotation in both directions during operation.

DFP

Adjust the DFP sensor shaft so that its keyway is pointing towards the top cover when the dancer is half
way through its travel.  This is an approximate adjustment, and is intended to center the sensor position
to allow maximum rotation in both directions during operation.

Summary of Contents for DFC-A

Page 1: ...m or Dancer control applications The DFC A provides a 0 to 10 vdc or 4 to 20 ma output to control a current to pressure transducer or a motor drive in torque mode Terminals are provided for the connec...

Page 2: ...r DFP 2 roll diameter sensor 10 kohm tension potentiometer All inputs and outputs have the negative lead referenced to ground 4 2 Sensor Setup See Figure 3 The DFP or DFP 2 position sensor should be a...

Page 3: ...ME full Counter Clockwise STOP MULT full Counter Clockwise 2 Set the external TENSION pot full Clockwise 3 Position the follower arm on an empty core 4 Adjust the CORE pot to obtain zero on the remote...

Page 4: ...E may be adjusted from 0 2 to 60 seconds 5 0 Dancer Applications 5 1 Electrical Connections Figure 5 shows the connections that are required for the basic dancer system They are 24 vdc power Current T...

Page 5: ...peat step 3 Calibration is complete and the DFC A is ready for operation Optional Adjustments Integrator Many machines run quite successfully after the above adjustments have been made If the dancer a...

Page 6: ...ating Counter Clockwise until the dancer stabilizes The POS1 pot may require readjustment several times in order to keep the dancer roll centered DEFINITION In the following steps the user will have t...

Page 7: ...for the Remote tension control DFP DFP 2 position sensor not wired properly or wires shorted Verify position sensor is wired properly and follow the calibration procedure in section 4 3 Voltage betwe...

Page 8: ...alibrated Follow the calibration procedure in section 5 3 Output full on or full off DFC A in PID mode and RUN STOP switch is not wired properly Verify RUN STOP switch wiring PID mode needs a RUN STOP...

Page 9: ...tude 0 to 2000 m Compatible Residual Current Device Types A or B IEC755 Worst Case Fault Current 2 0 amp dc Inputs Signal DFP or DFP 2 Potentiometer 1 to 10 kohm watt minimum Tension Potentiometer 10...