background image

2

FULL ROLL DIAMETER

CORE DIAMETER

DFP

3.0  Maintenance

The only maintenance that may be required on the DFC-A is fuse replacement.  Replacement of the fuse
requires first removing dc power, then opening the enclosure.  The enclosure must be re-installed to
maintain the IP rating.  The enclosure may be opened by inserting a flat blade screwdriver under the
retaining tabs in the base (See figure 2).

        

Figure 2                                                   

Figure 3

          Enclosure Top Removal                                                      Follower Arm Setup

4.0   Follower Arm Applications

4.1   Electrical Connections

Figure 4 shows the connections that are required for the basic follower arm system.  They are:

24 vdc power input
Current-to-Pressure Transducer or a motor drive in torque mode
DFP or DFP-2 roll diameter sensor
10 kohm tension potentiometer

All inputs and outputs have the negative lead referenced to ground.

4.2   Sensor Setup (See Figure 3)

The DFP or DFP-2 position sensor should be at the center of rotation when the follower arm is halfway
through its travel.  This is an approximate adjustment and is intended to center the sensor position to
allow maximum rotation in both directions during operation.

DFP

Adjust the DFP sensor shaft so that its keyway is pointing towards the top cover when the
follower arm is half way through its travel.

DFP-2

To find the electrical center point of pot rotation, use a digital multimeter type ohm meter to
 measure from the white wire (wiper), to the red or black wire.  Turn the potentiometer shaft
 until the meter reads 500 ohm.  Install the DFP-2 sensor so the meter reading is 500 ohms
 when the follower arm is halfway through its travel.

Summary of Contents for DFC-A

Page 1: ...m or Dancer control applications The DFC A provides a 0 to 10 vdc or 4 to 20 ma output to control a current to pressure transducer or a motor drive in torque mode Terminals are provided for the connec...

Page 2: ...r DFP 2 roll diameter sensor 10 kohm tension potentiometer All inputs and outputs have the negative lead referenced to ground 4 2 Sensor Setup See Figure 3 The DFP or DFP 2 position sensor should be a...

Page 3: ...ME full Counter Clockwise STOP MULT full Counter Clockwise 2 Set the external TENSION pot full Clockwise 3 Position the follower arm on an empty core 4 Adjust the CORE pot to obtain zero on the remote...

Page 4: ...E may be adjusted from 0 2 to 60 seconds 5 0 Dancer Applications 5 1 Electrical Connections Figure 5 shows the connections that are required for the basic dancer system They are 24 vdc power Current T...

Page 5: ...peat step 3 Calibration is complete and the DFC A is ready for operation Optional Adjustments Integrator Many machines run quite successfully after the above adjustments have been made If the dancer a...

Page 6: ...ating Counter Clockwise until the dancer stabilizes The POS1 pot may require readjustment several times in order to keep the dancer roll centered DEFINITION In the following steps the user will have t...

Page 7: ...for the Remote tension control DFP DFP 2 position sensor not wired properly or wires shorted Verify position sensor is wired properly and follow the calibration procedure in section 4 3 Voltage betwe...

Page 8: ...alibrated Follow the calibration procedure in section 5 3 Output full on or full off DFC A in PID mode and RUN STOP switch is not wired properly Verify RUN STOP switch wiring PID mode needs a RUN STOP...

Page 9: ...tude 0 to 2000 m Compatible Residual Current Device Types A or B IEC755 Worst Case Fault Current 2 0 amp dc Inputs Signal DFP or DFP 2 Potentiometer 1 to 10 kohm watt minimum Tension Potentiometer 10...

Reviews: