Model OE-10
Installation, Operation and Maintenance
Page
6
Rev. 4/20/07
(6) 3/8" FLAT WASHERS
(6) 3/8" FLAT WASHERS
(6) 3/8" FLAT WASHERS
(6) 3/8" FLAT WASHERS
HAIRPIN COTTER PIN
HAIRPIN COTTER PIN
HAIRPIN COTTER PIN
HAIRPIN COTTER PIN
PIVOT HOLE FOR
11'-11"
OVER ALL WIDTH
OVER ALL WIDTH
11'-6 1/2"
PIVOT HOLE FOR
Fig 4b –
Overhead Limit Switch Sub-Assembly
IMPORTANT:
There are two overall width
settings. Insure to place the limit switch and
shutoff bar in the proper pivot holes as shown in
Fig’s 4a & 4b.
16) Repeat
procedure 12
for shut-off bar. Insert
shut-off bar in switch tube on power column
side and take other end to idler side. Attach
shut-off bar to idler column in same manner
as switch tube.
Insure that both switch tube and shut-off
assemblies pivot freely for proper
operation.
17) Assemble the sheaves and spacers onto the
sheave pin as shown in
Fig 5
. Set in cradle
with all assembly parts between the two
plates.
SHORT SHEAVE SPACER
SHEAVE
SHEAVE PIN
LONG SHEAVE SPACER
SHEAVE
SHORT SHEAVE
WASHER
WASHER
WASHER
WASHER
SPACER
Fig 5 –
Sheave Assembly
S
YNCHRONIZER
C
ABLES
18) Attach one end of synchronizing cable to
carriage. See
Fig 7
for proper attachment.
19)
Route cable up and over sheave in
overhead. Follow across to other sheave on
opposite column. Route down through
carriage to sheave in bottom of column.
Route under sheave and up to cable
attachment. Use
Fig 7
for proper attachment.
20) Repeat for opposite side.
IMPORTANT
:
4 1/2" lg STAND-OFF
FOR
11'- 6 1/2" WIDTH
SETTING ONLY
IMPORTANT
:
4 1/2" lg STAND-OFF
FOR
11'- 6 1/2" WIDTH
SETTING ONLY
IMPORTANT
:
4 1/2" lg STAND-OFF
FOR
11'- 6 1/2" WIDTH
SETTING ONLY
IMPORTANT
:
4 1/2" lg STAND-OFF
FOR
11'- 6 1/2" WIDTH
SETTING ONLY
Fig 7 –
Cable Assembly
IMPORTANT:
Stand-Offs to be used only on the 11’– 6 ½”
Overall Width Setting.
P
OWER
U
NIT
& H
YDRAULIC
L
INES
5/16"-18 HEX NUT
(4) REQUIRED
5/16"-18 HEX NUT
(4) REQUIRED
5/16"-18 HEX NUT
(4) REQUIRED
5/16"-18 HEX NUT
(4) REQUIRED
Fig 8 –
Power Unit Mounting
21) Mount Power Unit to power column as shown
in
Fig 8
. The mounting hardware, (4)
5/16”-18 hex nuts, are pre-installed on power
unit mounting bracket.
22) Uncoil Idler side hose and route through the
Idler Side column extension as shown in
Fig
9a
. taking care to avoid the synchronizing
cables and hydraulic cylinder path. Remove
slack and tighten all 3 clamps. Route hose
across overhead avoiding the synchronizing
cables and down through the Power Side
column extension as seen in
Fig 9b
. Do Not
Tighten Clamps at this time.
A2151_MAGNUM.doc