47
JACK MAINTENANCE
The following procedures should be performed at least annually.
SIDE-WIND MODELS
•
The internal gearing and bushings of the jack must be kept lubricated. Apply a small amount of automotive
grease to the internal gearing by removing the jack cover, or if equipped, use a needle nose applicator or
standard grease gun on the lubrication point found on the side of the jack near the crank. Rotate the jack
handle to distribute the grease evenly.
•
A lightweight oil must be applied to the handle unit at both sides of the tube.
•
If equipped, the axle bolt and nut assembly of the caster wheel must also be lubricated with the same light
weight oil.
TOP-WIND MODELS
•
Apply a lightweight oil to the screw stem.
CHECKING GENERATOR DRIVE PLATE TORQUE
Follow the procedure below to check the torque of the generator drive plate bolts in accordance with the maintenance
chart.
1. Disconnect the engine starting battery.
2. Remove the generator fan guard.
3. Torque each of the drive plate bolts to the appropriate specification shown in the table below.
4. Reinstall the generator fan guard. Reconnect the battery.
Unit
ft-lb (Nm)
Unit
ft-lb (Nm)
MMG25FHI
36 (49)
MMG45FHK
41 (56)
MMG35FHD
41 (56)
MMG55FHD
41 (56)
2LO
*UHDVH
2LO
*UHDVH
2LO
2LO
2LO
*UHDVH