43
•
Verify all circuit breakers are open (OFF, “O”).
•
Activate (push in) the “EMERGENCY STOP” switch.
•
Disconnect the negative (-) terminal on the battery.
•
Attach a “DO NOT START” sign to the control panel. This will notify everyone the unit is being serviced and
will reduce the chance of someone inadvertently trying to start the unit.
•
If the unit is connected to a remote start or transfer switch, make sure the remote switch is also off and tagged.
•
Never wash the unit with a high pressure hose or with any kind of power washer.
•
Never wash the engine block or fuel tank with a power washer or steam cleaner. Water may enter the cabinet
and collect in the generator windings or other electrical parts, causing damage.
•
If the unit is stored outside, check for water inside the cabinet and generator before each use. If wet, dry the
unit thoroughly before starting.
BASIC MAINTENANCE SCHEDULE - ISUZU ENGINE
Refer to the original equipment manufacturer’s operating manual for a complete list of
maintenance requirements. Failure to comply with the procedures as described in the engine
operator’s manual will nullify the warranty, decrease performance and cause equipment
damage or premature equipment failure.
Use the schedule in the following table as a guide for regular maintenance intervals. For additional or replacement
copies of the engine operator’s manual, contact an authorized dealer in your area.
Item
Daily
250
Hrs.
500
Hrs.
Check oil level
Check coolant level
Check fuel level
Drain fuel filter
Check tire pressure
Check all electrical connections
Clean battery
Check fan belt tension (Replace if necessary)
Inspect radiator fins for debris, clean as required
Preheating condition check
Check engine starting conditions and noice conditions
Check exhaust smoke condition
Replace engine oil
Replace fuel filter element
Clean water sedimenter element
Electromagnetic pump filter replacement or cleaning
Check fan belt tension (Replace if necessary)
Oil filter element replacement
Replace air filter element
Lubricate leveling jacks
Check generator drive plate torque (Refer to
“Checking Generator Drive
Plate Torque” on page 47
)