©2007 Magnum Energy Inc.
Operation
04 BM: Status
- This menu selection displays “read-only” displays that give
the current operating status of the Battery Monitor (BM). This selection also
provides information to know if there is a power-up fault condition.
Figure 5-3, METER: 04 BM: Status Display
BM: Pwr-up Fault
- The BM faulted when it was powered-up; the fault
occurred because the power-up self-test failed. See the Troubleshooting
section.
BM: No Comm
- The BM is not communicating with the remote. This
typically means a ME-BMK is not installed in the system. If installed, view
the Sense Module LED and use Table 5-1 to help determine the issue.
BM: Ready
- The BM is connected and actively monitoring the battery
system.
05 BM: SETUP -
This menu allows the battery’s charging ef
fi
ciency to be
automatically determined or manually selected; normally the charging ef
fi
-
ciency is automatically calculated (default setting is “Auto”). If you know your
battery’s ef
fi
ciency and want information on changing this setting from the
“Auto” selection, return to the SETUP section.
06 BM: TECH
- These menu selections allow you to access system informa-
tion used to assist service technicians in troubleshooting the Battery Monitor
or the charging system..
Figure 5-4, METER: 06 BM: TECH Selections
BM Rev
- This “read-only” menu displays the
fi
rmware revision level of
the connected Battery Monitor. If the Battery Monitor is not connected or not
communicating, the display will show “0.0”.
•
•
•
•
Status...
BM: No Comm
Status...
BM: Pwr-up Fault
Status...
BM: Ready
METER
press
Status…
04 BM: Status
rotate to
press to select
rotate to
desired
selection :
Status...
BM Rev: **
Status...
Min DC: **
Status...
Max DC: **
press to leave
METER
press
Status…
06 BM: TECH
rotate to
press to select
rotate to
desired
selection :