7.0 Specifi cations
18
©2007 Magnum Energy Inc.
0.
33"
2.40"
1.25"
0.91"
4.05"
1.75"
3.25"
1.50"
1.25"
1.75"
0.56"
0.75"
3/8-16 x 5/8" Bolts (9/16" head)
8/32 x 3/8" slotted screw s
0.60"
ø
.20"
S ense M odule
D C S hunt
Figure 7-1, Dimensional Specifications
Table 7-1, Specifi cations
Sense Module/Meter Specifi cations
DC Volts
7.00 - 70.00 volts (±0.02 volts)
DC Amps
±0.1 to 999 (±1.0%)
Battery SOC %
0 to 100% (1% increments)
Power Draw
18 mA typical
AH I/O (In/Out)
±32768 amp hours (1 AH increments)
rAH Out
(Resettable Amp-
Hours Removed)
0 to 65,535.0 amp hours, resettable
(0.1 AH increments)
tAH Out
(Total Amp-Hours
Removed)
0 to 65,535,000 amp hours
(0.1k or 100 AH increments)
Min/Max DC:
7.00 to 70.00 VDC, resettable
Shipping Weight:
~2 lbs. (Includes Manual, Sense Module, DC shunt,
twisted pair wire and Communications cable)
Sense Wire
Twisted Pair (blue & orange), 5’ length, 18AWG wire
Comm. Cable
2-conductor, 10’ twisted pair, telephone standard
DC Shunt Specifi cations
Resistance:
0.1 milliohm (500 amps at 50 millivolts)
Continuous current:
410 amperes maximum
Overload current:
Can take overloads to 500 amps for less than 5 min-
utes if normally operated at less than 300 amps.