Operating the MM410/AVM-510A
6-13
SIGNAL ID (PAL)
Lets you select AUTO SIG ID, LIVE VIDEO, 75% COLOUR BARS, 100% COLOUR BARS,
MULTIBURST, CCIR 17/330, NATIONAL ITS, or CCIR18. When AUTO SIG ID is selected, the
AVM-510A automatically detects from the selected line what type of test signal is present. The line
number and type of test signal present appears in the upper-right corner of the AUTO MEAS SET
display screen.
FREQ RESP LIMITS
Lets you select and set frequency response limits. See Figure 6-2 and Figure 6-3 for a list of frequency
response limit options. Refer to “Parameters: Range, Accuracy, and Limits,” in Chapter 10, for their
associated nominal values.
MULTIBURST TIMINGS
Lets you select and set times for BAR, PEDESTAL, and Packet 1 to 6 for a custom multiburst setting.
See Figure 6-2 and Figure 6-3 for a list of multiburst timing options. Refer to “Parameters: Range,
Accuracy, and Limits,” in Chapter 10, for their associated nominal values.
PACKET FREQUENCIES
Lets you select and set frequencies for Packet 1 to 6 for a custom multiburst setting. See Figure 6-2
and Figure 6-3 for a list of multiburst timing options. Refer to “Parameters: Range, Accuracy, and
Limits,” in Chapter 10, for their associated nominal values.
NON LINEAR
Lets you select the MEASURE LINE, SIGNAL ID, or NON LINEAR LIMITS options.
MEASUREMENT LINE
Lets you select a line (1/3:10 to 2/4:262) that measurements can be taken from (1/3:7 to 2/4:612 for
PAL).
SIGNAL ID (NTSC)
Lets you select LIVE VIDEO, 75% COLOR BARS, 100% COLOR BARS, 75% SMPTE BARS,
FCC MULTIBURST, FCC COMPOSITE, NTC7 COMPOSITE, MULTIBURST or AUTO SIG ID.
When AUTO SIG ID is selected, the AVM-510A automatically detects from the selected line what
type of test signal is present. The line number and type of test signal present appears in the upper-right
corner of the AUTOMEASURE display screen.
SIGNAL ID (PAL)
Lets you select AUTO SIG ID, LIVE VIDEO, 75% COLOUR BARS, 100% COLOUR BARS,
MULTIBURST, CCIR 17/330, NATIONAL ITS, or CCIR18. When AUTO SIG ID is selected, the
AVM-510A automatically detects from the selected line what type of test signal is present. The line
number and type of test signal present appears in the upper-right corner of the AUTO MEAS SET
display screen.
NON LINEAR LIMITS
Lets you select and set non linear limits. See Figure 6-2 and Figure 6-3 for a list of non linear limit
options. Refer to “Parameters: Range, Accuracy, and Limits,” in Chapter 10, for their associated
nominal values.
Summary of Contents for AVM-510A Series
Page 16: ...About This Manual 1 4 Notes...
Page 34: ...Installation 4 6 Notes...
Page 48: ...Front Panel Operation 5 14 Notes...
Page 102: ...Viewing Waveforms Vectors and Pictures 7 30 Notes...
Page 126: ...Automatic Measurement AVM 510A 9 20 Notes...
Page 148: ...AVM 510A C For Component Measurements 12 4 Notes...
Page 158: ...Connector Pinouts B 4 Notes...
Page 162: ...Calibration D 2 Notes...