Appendix E: Specifications
●
40
CONTOUR Operating Instructions © 2013 Magnetrol International all rights reserved
Power Supply
The power supply will not connect to a DC distribution network.
Supply voltage
20
…
32 VDC
Power consumption
max 1.5W
Electrical protective measures
Protection
IP 67 according to IEC 60529
Approvals
ATEX
II 1/2D, Ex ibD/iaD 20/21 T110
°
C
II 2G Ex ia/ib IIB T4
cFMus
Intrinsically safe CL I, II, DIV I, GP CDEFG
Comply with the following approval standards:
CAN/CSA C22.2 No. 25, 1966
CAN/CSA C22.2 No. 157, 1992
CAN/CSA C22.2 No. 1010, 2004
CAN/CSA E61241-1-1, 2002
NEPSI
Ex ibD/iaD 20/21 T110
°
C
Ex ia/ib IIB T4
CE
EMC (2004/108/EC) Emission: EN 61326: 1997 (class B)
Susceptibility: IEC/EN 61326:1997 + A1:1998 + A2:2001 + A3:2003
NSR (73/23/EWG) EN 61010-1: 2001
FCC
Conformity to part 15 of the FCC regulations
FCC 47 CFR part 15:2007, subpart B, class A
The CONTOUR 3DS-xxxx-Axx-xx-xxx complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.