Physical Installation
● Assembly
and Mounting
CONTOUR Operating Instructions © 2013 Magnetrol International all rights reserved
15
Remove the cable clamp located at the
bottom inside the scanner as shown.
Gently
insert the antenna cable through the scanner head. Make sure not to
damage the (white) cable connector. This connector connects the transmission
signal from the electronic board to the transducers. Damage to the connector or to
the wires will result with malfunctioning operation of the scanner.
Insert the scanner head onto
the neck tube.
IMPORTANT:
When
inserting the scanner head
onto the neck tube, make
sure to push the head all
the way down until it fully
contacts the top of the neck tube.
NOTE:
It is recommended to lubricate the O-Ring on the neck tube prior to
installing the scanner head. This makes it easier to insert and properly locate
the scanner head over the tube neck.
NOTE:
The CONTOUR head may be installed in six different positions.
Tighten the front screw using a 4mm hex key and a 13mm
wrench.
Replace the cable clamp back to
position, between the antenna cable and
the electronic board.
2
3
4
5
6