The electrical wiring of the barrier must comply with the included drawings.
●
Only certified and trained electrical technicians may perform the electrical
connections
●
Only certified and trained electrical technicians may remove covers for
mains plug, mains receivers or wirings
●
Before repairing electrical failures disconnect fuse
●
Risk of bodily harms while closing the cover
●
As part of the maintenance work, the fixing bolts must be checked and
tightened, if necessary.
●
Current carrying components like transformers, solenoids, resistors, stator
housings of motors, lamps etc. shall not be touched while in operating-
temperature condition; this can cause skin burns
3. Product description
The MPT series of turnstiles are designed to control pedestrians entering or
exiting restricted areas outside in high security situations. The turnstile
consists of four different component parts (see fig. 1) It can be used for bi-
directional access control by means of keys or card readers (access control
devices in general). Entry and exit of the barrier can either be operated in
open, controlled or closed modus. The rotating centre column consists of 3 x
120 degree U bars. The controller, the drive units and the locking device are
mounted on top of the centre unit in a powder coated sheet metal enclosure,
where there is also space for additional access control equipment .Locking
and release of the centre is realized by an electro-mechanical locking device
with solenoids.