Pedestrian Pivot Barrier
MPP-112 / MPP-122 / MPP-132 / MPP-212 / MPP-222
Configuration of pedestrian barrier
5817,0016EN / Version 00
53
DIP S1.x
Function
Description
4 Safety
level
(continued)
High safety level:
At a high safety level, an additional
lead time is active to make complete passage in the
wrong direction more difficult. The lead time is the time
between activation and release of the lock. The lead
time increases with the angle.
When the lock is no longer pushed on when released,
the motor returns to the original and position.
Options
OFF: Low safety level
ON: High safety level
The hold-open time is the maximum time for which the lane
remains open after an opening signal if there is no one in
the lane. On expiry of the hold-open time, the pedestrian
barrier closes if no one has passed through.
Optionen
DIP
S3.2
DIP S1.5
DIP S1.6
Hold-open
time
OFF OFF 10
s
OFF ON 20
s
ON OFF 30
s
OFF
ON ON Endless
OFF OFF 5
s
OFF ON 7
s
ON OFF 9
s
ON
ON ON 15
s
5 and 6
Hold-open time
The setting "unlimited" keeps the passage open in the
requested direction until the passage has been completed.
7
Query software
version status
If this function is activated during operation, the version
status of the software is displayed cyclically on the
7-segment display.
Options
OFF: Normal operating display
ON: Version status of software is displayed
8 Home
position
At initial commissioning of the controller or when replacing
the motor controller, the "Home position" of the blocking
element has to be set first.
Options
OFF: Normal operating mode
ON: Dispose to learn
Table 7: DIP switch block S1