![background image](http://html1.mh-extra.com/html/magnetek/mini-mbt-transmitter-engineered/mini-mbt-transmitter-engineered_user-manual_3612842023.webp)
Enrange Mini-MBT Instruction Manual
June 2015
Page 23 of 37
position and release. The graphic user interface will display “Attempting” with a countdown of the time
while scanning for the receiver’s IR signal. If the receiver is in range and IR link is made, the message
will change to “Success”. The transmitter and receiver should be within one foot of each other to ensure
successful exchange of information via IR.
NOTE: The changes to the transmitter’s channel configuration and access code will not be saved until the
operator selects the Save and Exit option to exit the Setup Mode.
If the receiver is not in range, the scan will time out and the graphic user interface will display “Failed”.
The operator can reposition the transmitter and reattempt to establish the IR link with the receiver by
toggling the START position on the OFF-ON-START toggle multiple times.
NOTE: The access code and channel will not be updated to match the desired receiver until “Success” is
displayed. Once “Success” is displayed, subsequent “Failed” messages will not overwrite the access
code and channel obtained in the successful IR link until a new successful IR link is made.
The IR configuration function will only update channel and access code information if the receiver and
transmitter are programed at the factory with the same project identification number. If the
receiver/transmitter pairing is not programmed with the same project identification number, the graphic
user interface will display “Err Project ID” when an IR link is attempted. The IR link will not be successful
and the access code and channel information in the transmitter will not be changed.
If the receiver and transmitter IR pair are not operating in the same frequency band when an IR link is
attempted, the graphic user interface will display “Err RF Freq”. The IR link will not be successful and the
access code and channel information in the transmitter will not be changed.
4.2.2.11
Exit Without Save
If the user does not wish to save any of the configuration changes made, the Exit Without Save option
can be selected.
NOTE: None of the changes will be saved upon selection of this option. The transmitter will start up with
the last saved configuration settings.
4.2.2.12
Save and Exit
Selection of this option saves all changes and exits the Setup Mode.
Upon exit, the device will start up with the new configuration settings.