Enrange Mini-MBT Instruction Manual
June 2015
Page 15 of 37
3.2.1 Machine Stop and START Push Button
1. Ensure the Machine Stop is in the raised (pulled out) position.
2. After the unit has initialized (refer to Sections 3.2.4 and 3.2.5 for initialization), press the START
push button to enable communication with the receiver.
3.2.2 Machine Stop and ON-OFF-START Toggle
1. Ensure the Machine Stop is in the raised (pulled out) position.
2. Move the ON-OFF-START toggle to the ON position.
3. After the unit has initialized (refer to Sections 3.2.4 and 3.2.5 for initialization), press the ON-OFF-
START toggle to the START position to enable communication with the receiver.
3.2.3 Machine Stop, ON-OFF Toggle, START Push Button
1. Ensure the Machine Stop is in the raised (pulled out) position.
2. Move the ON-OFF toggle to the ON position.
3. After the unit has initialized (refer to Sections 3.2.4 and 3.2.5 for initialization), press the START
push button to enable communication with the receiver.
Figure 5: Machine Stop Switch and START push button
3.2.4 Transmitter Initialization (with Standard Status LED Indicator)
Upon turning the transmitter on, the Status LED lights up as a solid green color. Following the Status
LED turning on and illuminating green, the unit will perform a routine initialization.
During initialization, the Mini-MBT scans for any switches or motions that may be on during power up. If
any switches or motions are on, the failure will be displayed as a solid red Status LED, and the Mini-MBT
will power itself down.
After a successful initialization, the Mini-MBT will enter normal operation mode and display the normal
operating status LED indications. See Section 3.6 for more information on the normal operation mode
with standard status LED.