Flex 12EX2 Standard, AB and Tandem Instruction Manual
November 2017
Page 50 of 56
2. Once the transmitter is locked on to both receivers, rotate the selector switch to either A,
B, or A+B position for independent or simultaneous operation.
3. At the beginning of each shift prior to turning on the transmitter power, always check to
see if the selector switch is correctly positioned for the intended receiver or receivers.
4. For safety, there is a 2-second grace period after executing the PITCH command. This
means that after PITCH pushbutton is pressed, executing the START command on the
other transmitter within this 2-second grace period has no effect. To gain control of the
other receiver, you must first wait for up to 2 seconds after the PITCH pushbutton is
pressed on the other transmitter and then execute the START command.
Master Transmitter-A Takeover Procedure
Press PITCH
Rotate to B position
Rotate to START
→
→
(After 2 seconds)
Transmitter-B
Transmitter-A
Transmitter-A
Master Transmitter-B Takeover Procedure
Press PITCH
Rotate to A position
Rotate to START
→
→
(After 2 seconds)
Transmitter-A
Transmitter-B
Transmitter-B