4.2 Receiver
4.2.1
Receiver Channel Settings
Set the receiver channel by configuring the channel
dipswitch located on the decoder board. Only the first 6
dip positions are used for channel programming. The
system channels table in
illustrates which dipswitch setting corresponds to which
channel. Once the receiver channel is altered, make sure
to change the transmitter channel as well. The channel
on both transmitter and receiver must be identical in
order for the system to work (
, part B). When set to all zeros (000000), the
receiver becomes unassigned channel scheme (
, part A).
The dipswitch setting
“1 0 0 1 0 0”
corresponds to channel 36 in the system channels
table in
4.2.2
Output Relay Configurations
4.2.2.1 Output Relay Types
1. 2 output relays per motion – single speed only
Output relays with Forward (F) and Reverse (R) 1st speed only.
2. 3 output relays per motion – shared 2nd speed output relay
Output relays with Forward 1st speed (F1), Reverse 1st speed (R1) and Forward/
Reverse 2nd speed (F/R2). Forward and Reverse 2nd speed (F/R2) share the same
output relay.
7
1
4
2 3
5 6
8
Example:
Top position → “1”
Bottom position → “0”