Flex 12EX2 Standard, AB and Tandem Instruction Manual
November 2017
Page 28 of 56
* PB9…PB12
→
Pushbutton number.
* Normal
→
Normal momentary contact.
* A/1&2 - D/3&4
→
A/B pushbutton select function with designated LED indication.
4.1.10 Display Frequency Band
1. Rotate the power switch key to OFF ( 0 ) position.
2. With the STOP button elevated, press and hold PB2 and PB4 at
the same time.
3. Rotate the power switch key to ON ( I ) position.
4. Release PB2 and PB4 at the same time. The system will enter
Frequency Band Display mode.
5. The Status LED displays the preset transmitter frequency band
with orange, green and red blinks. An orange blink represents
the hundreds (+100), a green blink represents the tens (+010)
and a red blink represents the units (+001). For example,
4
orange blinks followed by
3
green blinks and
3
red blinks is 433 MHz.
6. Exit Frequency Band Display mode by rotating the power switch key to OFF ( 0 )
position.
4.1.11 Output Feedback Settings
Up to 4 assignable relay outputs can be programmed into the system and feedback to
the transmitter LED indicators during operation. These settings require using the
infrared IR programmer unit. Please contact Magnetek field service for more details.
155
1 5
5 Reds
Normal
Normal
C/1&2
D/3&4
156
1 5
6 Reds
Normal
Normal
D/1&2
D/3&4
Function
Number
Display Type
PB9
PB10
PB11
PB12