MAGNER 910 Operation Manual V1.1
Page 16 of 18
problem, press CLR key to come back into main display modes
interface.
(
7
)
ERROR 06
ERROR 05
TRAY : 2 FULL
PLEASE EMPTY THE TRAY
·When it displays ERROR 06, it means the Optical tube assembly for
second solenoid is counting abnormally. Please check 1) if the side
plate assembly is in good condition and the coins can run smoothly 2)
if the optical tube assembly of second solenoid is well connected 3) if
the optical tube assembly of second solenoid is broken 4) if the driving
board, main board and AD board is in good condition.
(
8
)
ERROR 07
ERROR 05
TRAY : 2 FULL
PLEASE EMPTY THE TRAY
When it displays ERROR 07, it means the optical tube assembly for
third solenoid is counting abnormally. Please check 1) if the side plate
assembly is in good condition and the coins can run smoothly 2) if the
optical tube assembly of third solenoid is well connected 3) if the
optical tube assembly of third solenoid is broken 4) if the driving board,
main board and AD board is in good condition.
(
9
)
BOX 2 FULL