background image

     

®

 Shanghai Yatai Instrument Ltd                                        JC Series Electric Counter User Manual 

 

Address: Marketing Department: 8F Rongxin Mansion, 1851 North Sichuan Road Shanghai China, Tel: 021-51053127; 51053128 

Technical support and Factory: No. 128 Zhenyuan Rd, Baoshan City industrial Park, Shanghai China, Tel: 021-36160962, 36160096 (English) 

Email

//[email protected]

                                                                                                        Website

HTTP://WWW

.yatai.sh.cn

     

 

 

JC Series Electric Counter – User Manual 

General Description   

JC series electronic counter provides excellent performance by 

using the single chip micro-processor with high accuracy, wide 
counting range, digital display, soft contact operating key, data 
protection during blackout, strong anti-disturbance capability, 
modern design of appearance, etc. 
      JC series electronic counter can be used in many industrial 
applications such as packaging, printing, pharmacy, food, textile, 
papermaking, ceramic, petroleum, chemical engineering, metallurgy, 
etc. It can also display and control other parameters like rotating 
revolution and length.

 

 

Model series

 

A:12DC

20

42VAC/DC

J C

  

S -

20

36×76 (Panel size)   

48

48×48  

72

72×72

80

80×160

Single preset model

Power Voltage:

B:187

242VAC

C: 85

264VAC

 

 
Technical Parameters and Functions 

1.

Mounting

panel mounting or socket mounting. 

2.

Power supply

4.5W

Single input impedance

≥5KΩ 

3.

Maximum counting frequency

high speed

5000times/s

medium 

speed

250 times/s

low speed

25 times/s. (duty ratio is 1:1)   

4.

Counting type

counting up and counting down according to user 

selection 

5.

Input signals and the frequency options: 

.Contact signal

For relay, distance switch, micro switch, the 

frequency should be set to low speed (30 times/s) when the signal 
duty ratio is 1:1. 

.Non-contact signal

For proximity switch, photoelectric switch, 

ect, the frequency can be set to either high (1000 times/s) or low(30 
times/s) according to requirement when the signal duty ratio is 1:1. 

.Pulse signal: For TTL circuit and impulse voltage (low level VL 

=0~1.3V, high level VH=4.5~30V). The frequency can be set to 
either high (1000 times/s) or low (30 times/s) according to 
requirement. 

6.

Modes for control output 

mode: When the meter counting value reaches its preset value, the 

output contact is emitted and continue counting.

 

mode: When the meter counting value reaches its preset value, the 

output contact is emitted and counting stops. 

mode: When the meter counting value reaches preset value, display 

is reset to zero automatically and meter counting repeats, and the 
control contact is activated until the mono-stable time is elapsed.   

 

( R)

 mode: When the meter counting value reaches its preset 

value, counting stops ,control contact acts as output, the control 
contact is activated until the mono-stable time is elapsed

display 

is reset to zero automatically and meter counting repeats. 

7.

anti-jamming intensity

3 level

IEC801

.

 

8. 

Data backup (optional): 

10 year. 

9

. Reset (to zero) types: The display values and control output 

reset simultaneously. 

Press the reset (to zero) key on the surface panel (only during 

counting)

 

 

Reset with the terminals(by short the RST and the COM 

pin),the width of the reset pulse

0.1S

; 

Automatic reset with mono-stable delay:

select from 0~99.9s. 

10.

 External power supply for sensor

DC12V

current value is 

listed in Table 1. 

11

.Contact capacity of the control output

3A/250VAC

for 

resistance load

12.

Operating environment

temperature 0

50

℃;

relative 

humidity≤95%(without dew)

。 

 
Specification

                                                                                                                                                           

1

 

Model 

Counting 

Range 

Functional Description 

DC output for 

sensors 

Size (mm) 

(H×W×L) 

Size of 

mounting 

hole(mm) 

(H×W) 

Inserted 

depth(mm) 

JC24S 

0~999999 

Options available including 
preset mode, counting 
frequency mode, counting 
mode, counting output mode, 
output mono-stable time delay

 

data back up with power failure 

12VDC/20mA 

24×48×62 

22.5×45 

58 

JM20S 

0~99999 

12VDC/20mA 

36×76×106(90) 

33×73 

100(84) 

JM48S 

0~999999 

12VDC/30mA 

48×48×85 

45×45 

78 

JM72S 

0~999999 

12VDC/30mA 

72×72×75 

68×68 

65 

JC80S 

0~999999 

12VDC/60mA 

80×160×80 

76×152 

65 

NOTE: JC20S socket length:106mm, insert depth 100mm; terminal type length:90mm, insert depth 84mm. 

 

Display Panel

                                                                                                                                       

 

JC20S

 COUNTER

PARAM ET ER

PRE SE T

CLEAR

         

JC48S

COUNTER

CLEAR

PARAMETER

PRESET

            

 

JM80S 

COUNTER

OUTPUT

PARAM ET ER

PRE SE T

CL EAR

PRESET

PARAMETER

                                                                                                                              

JC20S                            JC48S/JM72S                                  JC80S 

Reviews: