20
www.magmaweld.com
USER MANUAL | KULLANIM KILAVUZU
monoTIG 160ip
EN
3.3 Menu Structure
The statuses of the functions on or off according to the modes are as follows.
Operation
3.2 TIG Cycle
Gas
Pre-Flow
Pulse Frequency
Spot Welding Time
Gas
Post-Flow
Start
Current
Base
Current
Main C
urr
en
t
Main Curr
en
t
Current
Up-Slope
Pulse
Circuit
Rate
Current
Down-Slope
Final
Current
0-10 sec.
1 sec.
16
0.1-10 sec.
30-160 A
0.1-10 sec.
0-23 sec.
1 sec.
40 A
1 sec.
2 sec.
18
20
23
25
Start Current
Up-Slope Time
Main Current
Base Current
Frequency
Down-Slope Time
Final Current
Post-Gas Flow Time
Pre-Gas Flow Time
30-160 A
30-160 A
0.1-2000 Hz
30-160 A
30 A
80 A
15 Hz
30 A
17
19
21
24
Parameter
Range
MMA Welding
LED
Factory Setting