Revised January 2020
www.magnaflux.com
Page | 2-2
The inspection unit as supplied is internally wired for operation from a power source as designated on the
Magnaflux Data Plate (located on the front of the inspection unit). When connecting the unit all local codes
should be followed. External wiring directions for operation on the designated voltage are as follows:
1. Open right side panel where the white disconnect switch is located, as shown in Figure 2-1 below, or
Optional disconnect, to gain access to input power terminal block. A punch out is required through the
roof of the unit to feed the customer’s power line. The punch out would be located on the back right
corner of the unit.
WARNING: Turn off and lock-out the external disconnect switch (not normally supplied)
before opening the right side panel. Failure to disconnect incoming power could result in
severe electrical shock or death.
Figure 2-1
2. Connect external power source to the terminal block on the rear right side of the inspection unit, or the
top connectors in the Optional disconnect.
WARNING:
Magnetic particle baths can carry electrical current. Since operators will come in
contact with the bath during operation, proper grounding of the inspection unit is
essential. Failure to ground the inspection unit properly may result in an electrical shock
hazard. Check the ground connection with an ohmmeter. A reading of 0 ohms denotes
an acceptable ground connection.
Black Light Installation
(Optional Accessory)
Summary of Contents for CSV Series
Page 1: ...Revised January 2020 www magnaflux com Page 1 0 CSV SERIES...
Page 8: ...Revised January 2020 www magnaflux com Page 1 7 PAGE LEFT BLANK INTENTIONALLY...
Page 27: ...Revised January 2020 www magnaflux com Page 2 19 PAGE LEFT BLANK INTENTIONALLY...
Page 54: ...Revised January 2020 www magnaflux com Page 3 27 PAGE LEFT BLANK INTENTIONALLY...
Page 57: ...Revised January 2020 www magnaflux com Page 4 3 PAGE LEFT BLANK INTENTIONALLY...
Page 60: ...Revised January 2020 www magnaflux com Page 5 3 PAGE LEFT BLANK INTENTIONALLY...
Page 63: ...Revised January 2020 www magnaflux com Page 6 3 PAGE LEFT BLANK INTENTIONALLY...
Page 64: ...Revised January 2020 www magnaflux com Page 7 1 SECTION 7 HOOD INSTALLATION Not Applicable...
Page 65: ...Revised January 2020 www magnaflux com Page 7 2 PAGE LEFT BLANK INTENTIONALLY...