Magnadyne PL50 Installation Manual Download Page 11

11

87

86

85

30

White Wire with

Black Stripe

(SPST ALA984H 

Relay Not Supplied)

Output to Power Trunk Switch

To Co12 Volts

Input to Relay (+ or -)

Insert White Wire with Black Stripe 

 into the Eighth Socket

#2 Button Power Trunk Activation Using Optional 30 Amp Relay

Red Wire 

ALA-RPT

Relay Pack

Orange Wire

Output to Trunk Switch

Purple Wire

Input to Relay (+ or -)

Insert Red Wire into the First Socket

Insert Black Wire into the Eighth Socket

Black Wire 

#2 Button Power Trunk Activation Using Optional ALA-RPT Relay Pack

Dome Light Supervision Using Optional 30 Amp Relay:

(Applies to PL50 Only)

87

86

85

30

Orange Wire 

(SPST ALA984H 

Relay Not Supplied)

Output to Dome Light (+ or -)

To Co12 Volts

Input to Relay (+ or -)

Insert Orange Wire into 

the First Socket

Step 5: Optional Accessory Connections 

(Continued)

Dome Light Supervision Using Optional ALA-RPT Relay Pack: 

(Applies to PL50 Only)

Red Wire 

ALA-RPT

Relay Pack

Orange Wire

Output to Dome Light (+ or -)

Purple Wire

Input to Relay (+ or -)

Insert Black Wire into the First Socket

Insert Red Wire into the Second Socket

Black Wire 

Dome Light Supervision:

(Applies to PL60 Only)

Orange Wire Output to Dome Light (+ or -)

White Wire with Black Stripe Input to Relay (+ or -)

Insert Orange Wire into the First Socket

Insert White/Black Wire into the Second Socket

Summary of Contents for PL50

Page 1: ...t 1997 Magnadyne Corporation For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use Fax on Demand System INSTALLATION MANUAL Remot...

Page 2: ...ith the alarm kit is one pin switch and one mounting bracket To install the switch either in the truck or under the hood find a suitable location where the switch will make contact with the hood or tr...

Page 3: ...equiring positive voltage or more than 300mA to trigger the horn relay will require an additional relay to increase current capabilities Blue Wire with White Stripe Channel 3 Output Applies to PL60 On...

Page 4: ...hting dimmer switch Damage to the dimmer will result use a volt meter to test the connection point before connecting the red white wire While checking rotate the dimmer switch to make sure you do not...

Page 5: ...Wire Main Ground Input Connect the black wire directly to the frame of the vehicle Use a bolt and nut to secure the wire Scrape away any grease or paint that might prevent a good connection Yellow Wi...

Page 6: ...Brown Wire Unlock Green Wire Lock Blue Wire Unlock Violet Wire 3 Pin Black Plug ALA DL1 Relay Pack Power Door Lock Unlock Activation 3 Wire Positive Trigger Door Lock System Lock Out 12 Volts Input U...

Page 7: ...ne wire to lock and unlock the doors Example When the door lock controller sees a signal thru a resistor it will unlock If a signal is received without a resistor the doors will lock Some use 2 resist...

Page 8: ...r Ground To 12V or Ground Driver s Door Rear Door Passenger Door Switch Door Lock Relay Control Module Lock Unlock 12V Must Add ALA984H Relay Drivers Door Switch Cut Unlock Remaining Doors Unlock Driv...

Page 9: ...ection of this manual Page 17 ACC START OFF ON Cut Starter 2 Pin Plug from Control Module Unlock Driver s Door First Wiring for 5 Wire Ground at Rest Door Locking Systems 87 87A 85 86 30 87 87A 85 86...

Page 10: ...th White Stripe Output from Alarm Flashing Lights White Orange Wire Optional Dome Light Illumination and Lighted Pathway Illumination Output to Domelight or Input to Relay or White Purple Wire Orange...

Page 11: ...Using Optional 30 Amp Relay Applies to PL50 Only 87 86 85 30 Orange Wire SPST ALA984H Relay Not Supplied Output to Dome Light or To Constant 12 Volts Input to Relay or Insert Orange Wire into the Fir...

Page 12: ...e Valet Override Switch is in the Off Position S t e p 1 Switch in Off Position Switch in On Position Valet Override Switch Switch the Valet Switch On then Off 1 Time The horn siren will stop sounding...

Page 13: ...2 Regular Arm Dis 2 S t e p 6 To Code 2 Button Push the Valet Switch 2 Times Represent 1 Time On Off The LED will be solid red and the horn siren will chirp 1 time S t e p 7 2x Push the 2 Button The...

Page 14: ...rming Automatic Arming of Alarm Off 3 Silent Arming from 3 Button Transmitter s Aux Button Off 4 Safety Illumination Sentinel System Off R Disarm the Security System The LED will be off and the horn s...

Page 15: ...seconds after door is closed and rearm 60 seconds after remote disarm 4 Beeps Automatic Arming On Alarm will arm 70 seconds after door is closed and rearm 60 seconds after remote disarm 5 Beeps Automa...

Page 16: ...nner regardless of the alarm model Test each feature by following the procedures enclosed to insure proper operation Remote Panic 1 Press and hold the arm disarm for regular transmitters or panic butt...

Page 17: ...e security system is in the valet mode Note If the unit is in valet mode the LED will be on solid when the ignition key is on only When the ignition key is off the LED will flash once every 5 seconds...

Page 18: ...with the transmitter the locks will become locked 2 Disarm the alarm with the transmitter the locks will become unlocked RF Tamper Re Arm Note This feature is activated automatically when the alarm i...

Page 19: ...on deletable protective measure Channel 2 Output Press and hold the channel 2 activation button for 3 seconds The designated channel 2 output wire from the alarm become grounded for as long as button...

Page 20: ...View of Housing Dip Switches Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Valet Override Socket Blue 1 2 3 ON Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switc...

Reviews: