Power Requirements . . . . . . . . . . . . . . . . . . . . . . . .

12.5 Volts Negative Ground

Trigger Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Grounded Pin Switch, Positive Pin Switch, 

Electronic Sensor Ground, 0.6 Volt Current Drop

Current Requirements . . . . . . . . . . . . . . . . . . . . . . .

Less Than 15mA Armed or Disarmed

Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Programmable Automatic Arming Timer

Programmable Re-Arming Timer

60 Second RF Tamper Re-Arming Timer

5 Second Zone By-Pass Re-Activation Timer

Grounded Output Wire Capacity (White Wire) . .

500mA

Siren Output Wire Capacity . . . . . . . . . . . . . . . . . .

2  amps

Channel 2 Pulsed Output. . . . . . . . . . . . . . . . . . . .

300mA

By-Pass Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2  Zones

Transmitter Frequency . . . . . . . . . . . . . . . . . . . . . .

302mHz

Digital Code Combinations . . . . . . . . . . . . . . . . . .

500,000 Available

Code Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital Trinary

Transmitter Channels . . . . . . . . . . . . . . . . . . . . . . .

2  Channels

Receiver Channels . . . . . . . . . . . . . . . . . . . . . . . . .

No  More  Than 3

Ignition Controlled Door Locking: 

(Door lock activation must be installed)

When programmed on in “Remote Feature Programming”, ignition controlled locking is active 3 seconds

after the ignition key is set the on position, the door locks will automatically become locked. When the

ignition key is turned to the off position, the door locks will unlock.

Note: If a protected entrance (Door) is open when the ignition key is set to the on position, the door locks

will not lock. This is a non-deletable protective measure.

Channel #2 Output: 

(If Installed)

Press and hold the channel #2 activation button for 3 seconds. The designated channel 2 output wire

from the alarm will become grounded for as long as button #2 is pressed.

Channel #3 Output: 

(If Installed)

Press and hold the channel #3 activation button for approximately 3 seconds. After 3 seconds the alarm

will emit a ground signal from the channel #3 wire to operate the device connected to the channel #3

output wire of the alarm for as long as channel #3 button is pressed.

Dual Zone Sensor Pre-Warning Indicator: 

(If Installed)

1. Close all protected entrances and place the alarm in an armed condition.

2. Rap the vehicles body panels to activate the pre-warning zone of any dual zone type sensor.

3. When the pre-warning indicator is triggered, the horn/siren will beep 1 time.

Step 10:  Speciality Feature and Optional Equipment Testing

Specifications

Summary of Contents for CARBINE PLUS-5000

Page 1: ...yright 1999 Magnadyne Corporation INSTALLATION MANUAL R Vehicle Security For Technical Assistance 800 638 3600 For Fax on Demand Technical Assistance 800 994 9977 Must be a Registered Dealer to Use Fa...

Page 2: ...black wire coming from the siren to the frame of the vehicle In many cases you can ground the black wire to one of the screws used to secure the siren Run the remaining brown wire through the fire wa...

Page 3: ...horn relay will require an additional relay to increase current capabilities Blue Wire with White Stripe Channel 3 Output Connect the blue white wire to the device that will be operated from channel...

Page 4: ...witches For some vehicles it may be necessary to connect the violet wire directly to the switched turn on wire at the dome light The violet wire connects to positive switched circuits only Second Vaca...

Page 5: ...2 volts when the ignition key is in the on and start positions Do not connect the yellow wire to the acc wire coming from the ignition switch Switch 1 Power Door Lock Output Timing Set switch 1 to the...

Page 6: ...Brown Wire Unlock Green Wire Lock Blue Wire Unlock Violet Wire 3 Pin Black Plug ALA DL1 Relay Pack Power Door Lock Unlock Activation 3 Wire Positive Trigger Door Lock System Lock Out 12 Volts Input U...

Page 7: ...Multiplexing Door Locking Systems Some vehicle s Chrysler Mazda and Ford Probe and others use one wire to lock and unlock the doors Example When the door lock controller sees a signal thru a resistor...

Page 8: ...r Ground To 12V or Ground Driver s Door Rear Door Passenger Door Switch Door Lock Relay Control Module Lock Unlock 12V Must Add ALA984H Relay Drivers Door Switch Cut Unlock Remaining Doors Unlock Driv...

Page 9: ...ection of this manual Page 16 ACC START OFF ON Cut Starter 2 Pin Plug from Control Module Unlock Driver s Door First Wiring for 5 Wire Ground at Rest Door Locking Systems 87 87A 85 86 30 87 87A 85 86...

Page 10: ...pe Output from Alarm Flashing Parking Lights Alarm Status LED and LED Valet Switch Holder Plug In LED LED Harness 2 Pin White Valet Switch 2 Pin Blue LED Valet Switch Holder White Orange Wire Optional...

Page 11: ...Wire into the Eighth Socket Black Wire 2 Button Power Trunk Activation Using Optional ALA RPT Relay Pack Dome Light Supervision Using Optional 30 Amp Relay 87 86 85 30 Orange Wire SPST ALA984H Relay...

Page 12: ...Off Position S t e p 1 S t e p 2 ON S t e p 3 Turn On Ignition Push the Valet Switch 2 Times Represent 1 Time On Off The siren horn will stop sounding the parking lights will stop flashing and the LED...

Page 13: ...2 Regular Arm Dis 2 S t e p 6 To Code 2 Button Push the Valet Switch 2 Times Represent 1 Time On Off The LED will be solid red and the horn siren will chirp 1 time S t e p 7 2x Push the 2 Button The...

Page 14: ...ed Door Lock Unlock Off 4A 3 Button Channel 3 or Panic Operation Channel 3 3 Button Regular Transmitter Only 4B Panic Button Panic or Channel 3 Operation Panic 4 Button Code Hopping Transmitter Only R...

Page 15: ...Ignition is Turned On or Door Locks Door will not Unlock when Ignition is Turned Off LOCK UNLOCK 2 Beeps Door will Lock 3 seconds after Ignition is Turned On Door will Unlock when Ignition is Turned O...

Page 16: ...t position and the engine will crank over and start To test the basic functions of the alarm system all models repeat the following procedures 1 Turn off the ignition key and exit the vehicle closing...

Page 17: ...stem is in the valet mode Ignition is on 4b The LED will flash one every 5 seconds to indicate valet mode when the ignition is off How to Get Back to Security System Activation Mode 1 Place the igniti...

Page 18: ...or is by passed Four chirps Tamper indicator alarm is disarmed Power Door Lock Unlock If Installed 1 Arm the alarm with the transmitter the locks will become locked 2 Disarm the alarm with the transmi...

Page 19: ...cked When the ignition key is turned to the off position the door locks will unlock Note If a protected entrance Door is open when the ignition key is set to the on position the door locks will not lo...

Page 20: ...Horn Ground Dip Switches Back View of Housing Dip Switches Black Wire Antenna Do Not Ground Power Door Lock Harness Socket Black Valet Override Socket Blue 1 2 3 ON Black Wire Ground to Vehicle Frame...

Reviews: