4.2 Error Codes
It gives an error message when the mains voltage is wrong or thermal. If you do not want the welding performance to be affected during installation,
the parameters such as wire diameter, torch, consumables used in the torch, wire type, wire diameter and gas type should be considered.
ERR-T1
Thermal Error
• Let the machine on for a while in order to
cool down itself with the cooling fan. After is
cools enough, you can go on welding.
• Machine is overheated because of high
ambient temperature of exceeding duty cycle.
• Error/Errors may exist in any electronic card.
• Switch off and switch on. If the error still
exists, check the mains voltage whether it
is within the range of 340V-420V or not. If
the error still exists, contact the authorized
service.
E2
Power Module Error
Error Code
Error
Reason
Solution
Maintenance And Service
• Check the electronic card and mains voltage.
If the voltages are normal, contact the autho-
rized service.
• Check the mains voltage. If the mains voltage
is normal, contact the authorized service.
• Check the electronic card and mains voltage.
If the voltages are normal, contact the autho-
rized service.
• Check the mains voltage. If the mains voltage
is normal, contact the authorized service.
• Electronic card or network voltage drop can.
• There may be a drop in mains voltage.
• Electronic card or mains voltage there may be
a rise.
• There may be an increase in mains voltage.
E4
E16
Electronic Card or
Mains Voltage High
Low Mains
Voltage
E8
E32
Electronic Card or
Mains Voltage Low
High Mains
Voltage