ID 400E
EN
www.magmaweld.com
18
USER MANUAL | KULLANIM KILAVUZU
MAINTENANCE AND SERVICE
• Strictly follow the instructions contained in safety rules while servicing the machine.
• Before removing any screw on the machine for maintenance, power supply must be disconnected from the electric
lines and enough time should be allowed for capacitor discharging.
• Do not remove the warning labels on the device. Replace the worn/torn labels with the new ones. Labels
can be obtained from the authorized service.
• Check your clamps and cambles. Pay attention to the connections and the durableness of the parts. Replace the
damaged/defective parts with the new ones. Do not ever make aditions to/repair the cables.
• The Wire Feeding Mechanism must be kept clean and the roller surfaces must not be lubricated.
• Always remove any deposits on the mechanism with dry air each time you replace a welding wire.
• The consumables on the torch should be cleaned regularly. It should be replaced if necessary. Make sure that these
materials are original products for long-term use.
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems are encountered in your device.
Depending on the work load and contamination of your work environment, you can repeat the above processes more frequently.
4.1. Maintenance
Every 3 Months
4.2 Non-Periodic Maintenance
• Clean and tighten fasteners such as bolts and nuts.
• Check the electrode clamp and grounding clamp cables.
• Open the side covers of the machine and clean with low pressure dry air. Do not apply compressed air to electronic
components at close distance
Every 6 Months
Never weld with the covers of the welder open.