![background image](http://html1.mh-extra.com/html/magicfx/stadiumshot-iii/stadiumshot-iii_user-and-installation-manual_3502493024.webp)
24 MAGICFX
®
STADIUMSHOT III
—
User and Installation Manual
C
The STADIUMSHOT III is controlled with DMX. The DMX signal and the ARM signal
are combined.
4.
If controlled with DMX: Use the display and buttons or a RDM controller to
assign DMX addresses, see Chapter 1.
For more connection and configuration options, refer to the ARM SYSTEM
Configuration Manual (PART02323).
CAUTION
It is possible to fire the machine without connecting the
PowerCon TRUE1 female connector. Note that the compressor will
not work without connecting power and the warning LED will not
light up when enabling the ARM CONTROLLER. Pressure safety
checks will not work and it is possible to shoot confetti and
streamers at an unsafe pressure. See Section 1.8.
CAUTION
Do not connect more units to a single electrical circuit than the
installed fuse is able to handle. (Calculate the summed load with
the electrical data from Chapter 1)
NOTICE
Insert a TERMINATOR in the last ARM output of each line to close
the safety circuit. The ARM SYSTEM will not work when a line
remains open.
NOTICE
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal and reliabillity.
DMX
DMX + ARM
DMX CONTROLLER
ARM CONTROLLER
DMX INJECTOR
BEACON
STADIUMSHOT III
connect another machine
or insert terminator
POWER