10 MAGICFX
®
STADIUMSHOT III
—
User and Installation Manual
1.4
ARM CONTROL
NOTICE
The STADIUMSHOT III cannot be operated without connection to
an ARM CONTROLLER in an ARM SYSTEM.
The STADIUMSHOT III is configured for safety control with an ARM SYSTEM. The
STADIUMSHOT III cannot be operated without the safety signal from the control unit of
the ARM SYSTEM: The ARM CONTROLLER. When there’s no signal, the air valve from the
tank is switched off. The pressurized air can’t leave the tank, preventing the
STADIUMSHOT III from producing any high-risk SFX output. As a result, any related
hazard/or property damage is stopped and prevented.
The ARM CONTROLLER is equipped with a key switch to arm/disarm the connected
SFX machine(s), an emergency stop button, and a reset button. The ARM SYSTEM is
wired with EtherCON cables that carry the safety signal from the ARM CONTROLLER.
For more information about the ARM SYSTEM and to learn how to configure a
complete safety system, refer to the ARM SYSTEM Configuration Manual (PART02323).
For more information about the ARM CONTROLLER and to learn how to correctly set
up and use the ARM SYSTEM, refer to the ARM CONTROLLER User and Installation
Manual (PART01882).
1.5
DMX CONTROL
The STADIUMSHOT III is controlled with 1 enable adress and 1 operational address.
DMX Address
Address range
Enable address
1 – 512
Start address (Trigger)
1 – 512
DMX addresses
The enable address cannot be the same as the operational address. Operating of
these addresses results in the following:
DMX Address
DMX Value (decimal)
Result
Enable address
0
99
Device disabled
100
154
Device enabled
155
255
Device disabled
Start address
(Trigger)
0
199
No output
200
255
Fire
Operation of the DMX addresses
When you link multiple machines with DMX, we advise you to use the same enable
address for all machines.