background image

26  MAGICFX® SPARXTAR 

 

User and Installation Manual

EC DECLARATION OF CONFORMITY

DECLARATION OF CONFORMITY  

According to Annex III A Machinery Directive 2006/42/EC 

MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the 
product with the following specifications: 

Name machine 

: SPARXTAR® 

Type 

: MFX5001 

Voltage 

: 220-250Vac 50/60Hz 

Serial number 

: on product 

Year of construction 

: on product 

Is in conformity with the minimal safety regulations as stated in the following directive(s): 

 

LVD (2014/35/EU) Low Voltage Directive 

 

EMC (2014/30/EC) ElectroMagnetic Compatibility 

 

RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances 

 

WEEE (2012/19/EU) Waste Electrical & Electronic Equipment 

The following harmonized standards were applied: 

 

NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk 
assessment and risk reduction. 

 

NEN-EN-ISO 13732-1:2008 Ergonomics of the thermal environment -- Methods for the 
assessment of human responses to contact with surfaces -- Part 1: Hot surfaces. 

 

NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1: 
General requirements. 

 

NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3: 
Generic standards - Emission standard for residential, commercial and light-industrial 
environments. 

 Original declaration of conformity 

 Translation of the original declaration of conformity 

Name manufacturer 

: MAGIC FX B.V. 

Address  

: Schouwrooij 27, 5281 RE BOXTEL 

Country 

: The Netherlands 

 
CEO 

: B. Veroude 

Date 

: 17-12-2018 

Signature 

 

Summary of Contents for SPARXTAR SPARK FX

Page 1: ...SPARXTAR SPARK FX PART01213 rev 01 01 USER AND INSTALLATION MANUAL ENGLISH...

Page 2: ...brand names mentioned in this manual are registered trademarks of their respective owners LIABILITY MAGIC FX accepts no liability for claims from third parties arising from unauthorised use use other...

Page 3: ...control 7 1 7 Display panel 8 1 8 RDM capability 10 2 Spark safely 11 2 1 General safety rules 11 2 2 Rigging 11 2 3 Noise level 11 2 4 Safety symbols 12 2 5 Safety warnings 12 3 Let s spark 14 3 1 In...

Page 4: ...ed will result in death or serious injury This signal word is to be limited to the most extreme situations WARNING Indicates a hazardous situation that if not avoided could result in death or serious...

Page 5: ...PARXTAR can deliver sparks for a total duration of 9 up to 17 minutes depending on the set effect height The MAGICFX SPARXTAR is outfitted for operation with DMX and RDM in sequence with multiple mach...

Page 6: ...weight kg lb 11 7 25 8 Package Length mm in 416 16 4 Width mm in 416 16 4 Height mm in 333 13 1 Packaged weight kg lb 12 5 27 6 Environment Minimum Temperature C F 10 14 Maximum Temperature C F 50 12...

Page 7: ...ase contact MAGIC FX for additional possibilities 1 6 DMX CONTROL The MAGICFX SPARXTAR is controlled with 1 safety address and 2 operational addresses DMX Address Address range Control Safety address...

Page 8: ...effect is 40 seconds After this period the effect will stop automatically To start the effect again you must disable and re enable the Effect trigger NOTICE Always plug in a DMX Terminator into the DM...

Page 9: ...seconds of button inactivity Factory Defaults YES NO Purge Powder ON OFF blows powder out of the output pipe Unique ID Bootloader CRC Serial Number Build Date Lock Unlock Controller press and hold fo...

Page 10: ...upported by the MAGICFX SPARXTAR Parameter ID Discovery GET SET DISC_UNIQUE_BRANCH X DISC_MUTE X DISC_UN_MUTE X DEVICE_INFO X SUPPORTED_PARAMETERS X SOFTWARE_VERSION_LABEL X DEVICE_MODEL_DESCRIPTION X...

Page 11: ...ation 2 1 GENERAL SAFETY RULES Only authorised persons may work with the MAGICFX SPARXTAR Do not use the MAGICFX SPARXTAR if there are people or animals in the direct output Make sure that children un...

Page 12: ...ur website for detailed safety instructions WARNING Make sure there are no objects near the machine and within the output distance that can be damaged or catch fire by the emitted powder and sparks fr...

Page 13: ...e all safety symbols are correctly in place see section 2 4 CAUTION The output pipe heats up during operation and causes burns when touched Do not touch the output pipe of a recently powered machine C...

Page 14: ...y level surface 2 Inspect the machine and remove any foreign objects and material that will block or obscure the output pipe or the air inlets of the machine during operation 3 Take the necessary safe...

Page 15: ...for mounting on top of an upright truss see the User and Installation manual of the MAGICFX BASEPLATE II PART01575 1 Screw two clamps into threaded holes on the bottom of the machine Use two M10 twen...

Page 16: ...16 MAGICFX SPARXTAR User and Installation Manual 2 Mount the clamps firmly on a truss 3 Secure the MAGICFX SPARXTAR onto the truss...

Page 17: ...ine during operation 6 Take the necessary safety precautions including a Creating a safety zone with a distance of 3 m around the effect of the MAGICFX SPARXTAR and a clearance of 2 m from the set eff...

Page 18: ...ays wear eye protection when you come near a powered machine CAUTION The output pipe heats up during operation and causes burns when touched Do not touch the output pipe of an installed or recently op...

Page 19: ...MAGICFX SPARXTAR User and Installation Manual 19 3 Open the powder bag s and fill the hopper with powder maximum of two bags 4 Close and lock the lid of the hopper...

Page 20: ...20 250Vac 50 60Hz power source The machine starts heating and the fan starts blowing 3 Connect the female connector of a 5 pole DMX cable in the DMX input 4 Connect the other end of the DMX cable to y...

Page 21: ...ine 3 Connect a DMX cable to the DMX output 4 Connect the other end to the DMX input of the next machine 5 Use the buttons or a RDM controller to assign DMX addresses see Chapter 1 6 Repeat step 1 to...

Page 22: ...esired initial height of the output see Section 1 6 5 Make sure that the prescribed safety zone is clear 6 Activate the DMX safety address Directly after activating the device will check automatically...

Page 23: ...kes 10 seconds and will stop automatically 3 When all particles are removed set the DMX value for Effect trigger between 0 and 63 to stop 4 Deactivate the safety address The FX LED indicator on the ma...

Page 24: ...perature reached its maximum allowed temperature Let the effect inactive for a minute 121 Orientation of device out of safe bounds Keep the device within previously described safe bounds Always contac...

Page 25: ...rge Alternatively in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product Disposing of this product correctly will help save valuabl...

Page 26: ...WEEE 2012 19 EU Waste Electrical Electronic Equipment The following harmonized standards were applied NEN EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment and risk r...

Page 27: ......

Page 28: ...WWW MAGICFX EU...

Reviews: