Updating MobileMapper CX OS Firmware
The current version of MobileMapper CX Operating System
(OS) firmware can be downloaded from ftp.magellangps.com
in the
/Mobile Mapping/MM CX/Firmware/OS/
folder.
1. Turn on MobileMapper CX and either attach it to external
power or make sure that there is at least a 25% charge in
the battery (tap
Start>Settings>Control Panel>Power
).
2. Copy the OS firmware file with the *.nbx file extension
(e.g., NK_x_xx.nbx) to an SD card.
Note that OS firmware must be loaded from an SD card.
Do not copy the *.nbx file to MobileMapper CX’s MyDevice
folder.
3. With the SD card inserted into MobileMapper CX, double-
tap the
My Computer
icon on the desktop and then the
Win-
dows
folder.
4. Scroll to the bottom of the Windows folder and double-tap
the
OSLoader
icon to launch the program (OSLoader.exe).
You will see a message saying: “
Please choose a new image
file. The image file cannot be in the MyDevice directory.
”
5. Tap
OK
.
6. On the Open file screen, browse to the SD card, tap the
OS firmware file and tap
OK
in the upper right of the
screen.
7. When you see the “
Are you certain that you want to update the
operating system?
” message, tap
Yes
.
You will now see a progress bar on the OS Loader screen.
It takes a few minutes to upload the firmware.