40
Programming Guide
Alarm Relay and PGM Connection
s
AC Power & Backup Battery Connections
Transformer Requirements Table
Connecting Magellan to Winload
Transformer:
Amseco XP-1620
16VAC
20VA *
*not verified by UL
Recommended: 16VAC
40VA
UL: Basler
BE156240CAA007
MG5000 DC Power
Supply rated at:
1.2A
1.5A
Auxiliary Supply can
provide a maximum of:
typ: 600mA
max: 700mA
typ: 600mA
max: 700mA
UL installations: typ.
200mA
Acceptable Battery
Charge Currents
(section [127] option [5])
350mA
350mA / 700mA
Partial view of MG5000
control panel
UL Warning:
A 12Vdc / 7Ah battery
is required to comply
with UL fire
requirements.
Caution:
Disconnect battery
before replacing the
fuse.
Warning:
Improper connection
of the transformer may
result in damage to the system.
Rechargeable Battery
UL/ULC - 12Vdc / 4Ah or 7Ah
Back view of the
Magellan console.
Computer
containing
WinLoad
software
306
Adapter
4-pin
connector
cable
Standard
DB-9 cable
(9-pin serial
cable)