![Magellan MG5000 Programming Manual Download Page 25](http://html2.mh-extra.com/html/magellan/mg5000/mg5000_programming-manual_3420243025.webp)
Magellan
25
System Timers
[705]
General Zone Options 1
Option
OFF
ON
[1]
ATZ zone doubling
N
Disabled
N
Enabled
[2]
ATZ wiring options
N
Series
N
Parallel
[3] & [4]
[5]
Generate tamper on bypassed zone
N
No
N
Yes
[6] & [7]
[8]
Generate supervision on bypassed zone
N
No
N
Yes
[706]
General Zone Options 2
Bold
= Default setting
Option
OFF
ON
[1]
Check-in supervision time
N
24 hours
N
80 minutes
[2]
EOL resistors
N
Disabled
N
Enabled
[3]
Zone Input 1 becomes a 2-wire smoke input
N
Disabled
N
Enabled
[4]
to
[6]
Future use
N/A
N/A
[7]
&
[8]
N/A
N/A
N/A
Section
Data
Description
[710]
____/____/____
(000 to 255) seconds
Entry delay 1 (default 045)
[711]
____/____/____
(000 to 255) seconds
Entry delay 2 (default 045)
[712]
____/____/____
(000 to 255) max 15
Auto zone shutdown counter (Default 005)
[713]
____/____/____
(000 to 255) seconds
Intellizone delay (default 048)
[714]
____/____/____
(000 to 255) minutes
Recycle alarm delay (default 000)
[715]
____/____/____
(000 to 255)
Recycle alarm counter (default 000)
[716]
____/____/____
(000 to 255) minutes
Keypad lockout delay (default 000)
[717]
____/____/____
(000 to 255) attempt before locking
Keypad lockout counter (default 000)
[718]
____/____/____
(000 to 255) seconds
Remote panic disarm lock delay (default 000)
[719]
____/____/____
(000 to 255) days
Closing delinquency delay (default 000)
[720]
____/____/____
(000 to 255) seconds
Sleep Arm Alarm Delay (default 015)
[3]
[4]
RF Zone Tamper Recognition Options Keypad / Bus Module Tamper Recognition Options*
OFF
OFF Disabled
TROUBLE
ONLY
OFF
ON
TROUBLE
ONLY
TROUBLE
ONLY
ON
OFF When disarmed:
TROUBLE
ONLY
When armed: Follow zone’s alarm type
TROUBLE
ONLY
ON
ON
When disarmed:
AUDIBLE
ALARM
When armed: Follow zone’s alarm type
AUDIBLE
ALARM
* Tamper recognition of keypad / bus module only if section
[700]
option
[7]
is enabled.
[6]
[7]
RF Zone Supervision Options
Keypad / Bus Module Supervision Options
OFF
OFF Disabled Disabled
OFF
ON
TROUBLE
ONLY
TROUBLE
ONLY
ON
OFF When disarmed:
TROUBLE
ONLY
When armed: Follow zone’s alarm type
TROUBLE
ONLY
ON
ON
When disarmed:
AUDIBLE
ALARM
When armed: Follow zone’s alarm type
AUDIBLE