![Magellan MG5000 Programming Manual Download Page 36](http://html2.mh-extra.com/html/magellan/mg5000/mg5000_programming-manual_3420243036.webp)
36
Programming Guide
Auxiliary supply trouble restore
3 3AA - System trouble restore
YQ - Power supply restored
Bell output current limit restore
3 321 - Bell 1 restore
YH - Bell restored
Bell absent restore
3 321 - Bell 1 restore
YH - Bell restored
Clock programmed
3 625 - Time/date reset
JT - Time changed
Fire loop trouble restore
3 373 - Fire trouble restore
FJ - Fire trouble restore
Fail to communicate with monitoring station
1 354 - Fail to communicate
YC - Communication fails
RF interference
1 344 - RF receiver jam detection
XH - RF Interference Restoral
Combus fault
1 333 - Expansion module failure
ET - Expansion trouble
Module tamper
1 145 - Expansion module tamper
TA - Tamper alarm
Bus fault restore
3 333 - Expansion module failure restore
ER - Expansion restoral
Module tamper restore
3 145 - Expansion module tamper restore
TR - Tamper restoral
Maintenance in
1 627 - Program mode entry
LB - Local program
Maintenance out
1 628 - Program mode exit
LS - Local program success
Closing delinquency
1 654 - System inactivity
CD - System inactivity
PGM RF supervision lost
1 381 - Loss of supervision- RF
US - Untyped Zone Supervisory
PGM RF supervision restore
3 381 - Loss of supervision- RF restore
UR - Untyped Zone Restoral
PGM RF tamper
1 145 - Expansion module tamper
ES - Expansion Device Tamper
PGM RF tamper restore
3 145 - Expansion module tamper restore
EJ - Expansion Device Restore
Paramedic alarm
1 1AA - Medical
MA - Medical Alarm
Cold start
1 3A8 - System shutdown
RR - Power up
Test report engaged
1 6A2 - Periodic test report
TX - Test report
PC software communication finished
1 412 - Successful - download access
RS - Remote program success
Installer on site
1 627 - Program mode entry
LB - Local program
Installer programming finished
1 628 - Program mode exit
LS - Local program success
Module RF low battery
1 384 - RF transmitter low battery
XT - Transmitter battery trouble
Module RF battery restore
3 384 - RF transmitter battery restore
XR - Transmitter battery restoral
Module RF supervision trouble
1 381 - Loss of supervision - RF
US - Untype zone supervision
Module RF supervision restore
3 381 - Supervision restore - RF
UR - Untyped zone restoral
System Event
Default Contact ID Report Code
when using sections [790] to [795]
Default SIA Report Code
when using sections [790] to [795]