3. Accidents prevention  

3.1. The instructions furnished in this manual don’t replace in any way the norms related to the safety,  to the 
installation and the use, to the technical data or the norms in force in the nation of installation   or use or the 
norms dictated of the common sense.  
3.2. Technicians or maintenance technicians are obliged to notify any possible defects or deteriorations  that 
are able, in any way, to compromise the original safety of the plant.  
3.3. The serial high pressure cleaner is not equipped for working in environments characterized by  particular 
conditions  of  inflammability  or  explosiveness;  flameproof  equipment  is  supplied  only    and  exclusively  on 
specific  request.  It  is  forbidden  to  install  the  high  pressure  cleaner  in    environments  where  inflammable 
materials are present or with particles it suspended in the air:  acids, inks, varnishes, resins, solvents, plastic 
subjects, etc.; follow the norms imposed by the  fire department.  
3.4. The high pressure cleaner and its plant as the place and the environment, are forcedly exposed  to the 
water  and the damp that  injure the natural conditions of isolation of the  plant.  Don’t use   therefore unsafe 
electric  cables,  thorns  or  plugs,  and  sockets;  check  the  integrity  and  the  insulation    of  the  electric  cable, 
t

ogether with the equipment of the operators. Don’t absolutely touch the  thorn or the plugs with wet hands or 

feet.  To  avoid  accidental  switching  on,  turn  the  interrupter  on  OFF  before  inserting  or  disconnecting  the 
power  supply.  Don’t  pull  the  high  pressure  cleaner  using  the  electrical  cable  or  extract  its  thorn  from  the 
socket.  
3.5. Use with extreme care the chemical detergents not to deteriorate the environment (degradability  
90%),  parts  or  components  of  the  machine,  according  to  the  updating  of  the  legislative  decree.    Besides, 
always  check  the  degradability  and  the  aggressiveness  of  the  used  detergents.  Never  use  acids,  inks, 
solvents, liquid oily, varnishes, resins, etc…  
3.6

. The “cold” starting of the high pressure cleaner can cause some serious damages to the pump and the 

circuits;  the  standstill  prolonged  at  temperatures  under  0°C  could  cause  breakups  and    damages  to  the 
pump and the pipes; therefore the emptying of the machine is advisable.  
3.7. Always protect the high pressure cleaner from the atmospheric agents, from the cold and from the frost.  
3.8. Never direct the jet of water towards people (not even to clean their clothes or their shoes) or   animals, 
nor the machine itself or any objects under electrical tension.  
3.9.  Lance  and  gun,  although  equipped  with  proper  hilts,  have  a  modest  counterblow  (about  22N)  to  the 
departure  of  the  jet;  hold  them  with  strength  with  both  hands.  Never  touch  the  jet  of  water  during  the 
operation of the high pressure cleaner.  
3.10. If some defects, damages or deteriorations on the machine are found, disconnect it immediately,   and 
call an assistance authorized center or the supplier.  
3.11

. Don’t leave never, without overseeing, the high pressure cleaner working in presence of children.  

3.12. ATTENTION: If used in the correct way and it is in a good state, the high pressure cleaner sends forth 
a sonorous level of pressure (noisiness) of 101 dB. 
3.13. The maximum level of vibrations of the lance during the operation is 22m/sec

2

 

3.14. 

The high pressure cleaner has security devices for a safety use: 

-Pressure switch 
-Magnetothermic switch for motor protection 
-By-pass valve 
-Water Float (LASER MAX) 
-Electric controls 24V 
-Timed total stop system DSS 
 
3.15. The  high  pressure  cleaner  is  provided  with  a  timed  total  stop  system.  If  the  pistol  remains  closed  for 
more  than  10  sec.,  the  motor  will  stop.  The  motor  will  start  again  by  opening  the  pistol.  In  addition  the 
machine  will stop after 10 false starts (due to micro-leaks) or after 60 minutes without use. In this case the 
red light will blink. To restart the machine, turn OFF the switch Q1 and then, turn it ON again. 
3.16. ATTENTION: The by-pass security valve allows to regulate the flow and the pressure of the water. In 
addition it protects the pump from overpressure. The valve is set to the maximum allowed pressure and the 
nut  on  the  knob  is  sealed  with  paint.  Replacements,  reparations  and  new  regulations  must  be  made  by 
specific and authorized personnel. 
3.17  ATTENTION:  The  magnetothermic  switch  protects  the  motor  from  overloads.  In  case  of  overload  the 
magnetothermic switch stops the motor. To restart the motor, turn OFF the main switch and then turn it ON 
again. Replacements and reparations must be made by specific and authorized personnel with the machine 
unplugged from the electricity network. 
 
 
 

Summary of Contents for LASER Series

Page 1: ...ctions Manual Instructions for installation and use Manufactured by MAER IDROPULITRICI SNC Via Torre 65 2 24050 Torre Pallavicina BG Tel 0039 0363 996579 Fax 0039 0363 996688 maer maeridropulitrici co...

Page 2: ...ressure cleaner 6 Transport and unpacking 7 Installation 8 Connection to the electricity supply 9 Connection to the water supply 10 Switching on 11 Switching off 12 Maintenance 13 Pump 14 Demolition 1...

Page 3: ...echnical characteristics of the machine is positioned on the machine and it is always present Please make sure when you Purchase the high pressure cleaner that the machine has this nameplate of identi...

Page 4: ...the emptying of the machine is advisable 3 7 Always protect the high pressure cleaner from the atmospheric agents from the cold and from the frost 3 8 Never direct the jet of water towards people not...

Page 5: ...21 150 2175 21 5 5 7 5 400 70 154 LASER PRO200 15 200 2900 15 4 7 5 400 70 154 LASER PRO200 21 200 2900 21 5 5 10 400 80 176 LASER EKO120 8 120 1740 8 2 1 2 5 230 40 88 LASER EKO120 11 120 1740 11 3 3...

Page 6: ...l the parts and components In the case in which the machine is damaged please call the supplier and do not use the machine We remember that the elements used in the packing of the machine could hurt t...

Page 7: ...8 6 The cable is supplied without plug for the connection to the net this must be installed by the buyer which will verify that The plug is proper for the data of the voltage and the tension above des...

Page 8: ...is advisable especially in places with temperatures below 0 C 11 4 As soon as the water flow stops switch the machine off by acting on the switch Q1 11 5 ATTENTION the operation of the pump in absence...

Page 9: ...it is to destroy well the nameplate of identification together to every other document related to the same machine 15 Problems during the operation Problem Cause Solution The inlet hoses vibrate Forei...

Page 10: ...t hose 3 Flow adjustment tap 4 Delivery hose 6 Pump 7 Motor 8 Detergent tap 9 Detergent inlet hose 10 Tank 11 Filter 12 Nozzle 13 Microswitch 14 By pass valve 15 By pass hose 16 Pressure gauge 22 Pist...

Page 11: ...sons of returning and the type of malfunction 17 4 No modifications can be made to the high pressure cleaner In case of modifications made by the customer the warranty lapses 17 5 The MAER company dis...

Page 12: ...conforms to the instructions of the 2006 42 CE machine directive and to the other following CE directives Directive 2000 14 CE Acoustic inputs Directive 2002 44 CE Vibrations Directive 2004 108 CE ex...

Reviews: